background image

4

CAUTION

Do not use combustion appliances
in the path of the 
air outlet.

This may cause 

incomplete combustion

in the appliance.

Do not use the unit in places
where chemicals are used (such
as hospitals, factories,
laboratories or beauty salons).

Chemicals and solvents evaporated in the 
air may harm the unit and cause water in the
tank to leak, 

resulting in damage to

property

.

Do not use the unit for special
purposes, such as preservation of
food, art or scientific works.

This may negatively affect 

the quality of the items stored

.

Do not drain water continuously if
there is a possibility that
temperature around the hose could
drop to freezing point.

Water inside the hose may freeze and prevent
the water in the tank from flowing out.
The water may leak from the unit and 

damage

surrounding objects

.

Do not use the unit in places 
that may be subject to oil or
flammable gas leakage.

Such a leak around the unit may cause

combustion

and 

fire

.

Do not remove the 
Styrofoam from the 
floating element.

The floating element will not 
be able to detect a full tank 
resulting in water leakage, which may

damage surrounding objects or cause
electric shock and/or an electric leak

.

Do not wash the unit 
with water. Do not 
use the unit where it 
is likely to come in 
contact with water.

Exposure to water may result in 

fire or

electric shock caused by an electric leak 

.

Do not point air-flow from the unit
directly at the body.

If air-flow is directed at the
body for long periods, it
may 

harm one’s physical

condition

and 

lead to

dehydration

.

Install the unit in a location where
the floor is flat and stable.

If the unit falls over, the water collected in the
water tank may leak 

damaging surrounding

objects and in turn result in fire or electric
shock caused by an electrical leak

.

Grasp the plug and 
remove from the 
power socket.

When removing the plug from 
the power socket, do not pull on it diagonally
or by the cord as this may cause the
projections/wiring to be damaged resulting in

a short circuit, electric shock or fire

.

Before moving the unit always
switch it off, unplug it and remove
water from the water tank.

Moving the unit with water in its tank may
cause the water to leak and 

damage the

surrounding objects and in turn result in
electric shock and/or an electric leak

.

Do not cover the front or side air
intakes or the air outlet with cloth,
curtain, etc.

This results in poor ventilation and 
may cause 

heat generation/fire

.

Do not stand on, sit on or lean
against the unit.

The unit may tip over causing 

injury

.

Do not put vases or any other
objects filled with water on the unit.

Water may leak into the unit adversely affecting
electric insulation and cause 

electric shock

and/or fire by short-circuiting

.

Do not use the unit where it may be
exposed to direct sunlight or other
weather conditions. (This unit 
is for indoor use only.)

This may cause 

overheating,

electric shock and/or fire 
caused by an electric leak

.

Do not use the unit in narrow,
enclosed places such as inside
closets, between 
pieces of furniture, etc.

This results in poor 
ventilation and may cause 

heat generation and/or fire

.

Precautions (cont.)

e_mj_e16v_s1(01_09)_e33.qx  6/8/05 2:56 PM  Page 4

Содержание MJ-E16V-S1

Страница 1: ... ON To turn OFF Setting modes 10 AUTO LOW LAUNDRY LOW TEMP and AIR PURIFIER Drying inside 11 Using the OFF Timer 12 Removing Water from the Tank 12 Continuous Drainage 13 Maintenance 14 Replacing the Air Purifying Filter 15 Storage and Disposal 15 Troubleshooting 16 Specifications 18 In order to ensure correct usage please read this instruction manual carefully and retain it for future reference B...

Страница 2: ...ifier seem to collect less water in winter Q Why doesn t the dehumidifier operate Why does the unit stop operating suddenly A The unit might be in AUTO mode The unit automatically switches between dehumidifying airflow only and non operation 10 A When the temperature and humidity are low the amount of water collected is decreased In winter because the temperature is lower than in summer the effect...

Страница 3: ...ff the power plug and insert the plug firmly If the plug is not fully inserted into the socket dust may gather on the connectors which may cause fire and or electric shock Use 220 240V AC power sockets Connecting to power sockets other than 220 240V AC may result in fire and or electric shock Remove water that has collected in the tank Accidentally drinking the water or using it for other purposes...

Страница 4: ... one s physical condition and lead to dehydration Install the unit in a location where the floor is flat and stable If the unit falls over the water collected in the water tank may leak damaging surrounding objects and in turn result in fire or electric shock caused by an electrical leak Grasp the plug and remove from the power socket When removing the plug from the power socket do not pull on it ...

Страница 5: ...the power source when cleaning it When the unit is on the internal fan rotates at high speeds and may cause injury Unplug the unit from the power source when not using the unit for an extended period of time Otherwise it may cause fire and or electric shock caused by an electric leak Tips on dehumidifying Drain the water tank before use Drying laundry indoors Use the dehumidifier in a small enclos...

Страница 6: ... Floating element 12 Front door The water tank may contain water residue at time of purchase This is from final product testing at the factory and is not due to a defect Control Panel COLD COLD lamp The lamp lights up if the room temperature drops below 15 C Activating LOW TEMP mode is recommended 10 It is impossible to remove the back panel because the two spots shown are fastened with two specia...

Страница 7: ...This may be as often as once every 40 minutes The unit automatically shuts down and indicates with the lamp and sound that the water tank is full Empty the water tank Tank full lamp lights The unit beeps Airflow stops Lamp turns off After removing the water and replacing the tank the Tank full lamp will go off and then the unit will automatically return to operation mode When the Tank full lamp is...

Страница 8: ...d it becomes cold causing water droplets to form on the surface of the cup The dehumidifier takes advantage of this phenomenon to remove moisture from the air 1The unit draws air from the room cools it with its cooling coil causing the moisture to transform into water droplets 2The water droplets fall into the water tank 3The dehumidified air is reheated by the heating coil and then discharged The...

Страница 9: ... does not activate for 3 minutes when the unit is turned ON immediately after turning it OFF or plugging it into the power socket In order to protect the compressor When dehumidifying begins the operational noise increases Information Press If the room temperature falls below 15 C defrosting mode is activated once every 40 minutes for about 5 minutes causing water to drain to the tank The unit can...

Страница 10: ...e such as carbon monoxide cannot be removed with these filters Humidity level Room temperature C 50 20 30 27 60 Room temperature is below 27 C the unit automatically sets the humidity level according to the temperature Room temperature is above 27 C the unit lowers the humidity level to 50 then activates the blower The dehumidifier is reactivated when humidity rises to 60 When temperature humidifi...

Страница 11: ...pelled from inside the unit may smell due to odorants that were not caught by the filter dissolving in the water The OFF timer cannot be set during drying inside Information OFF Regular Regular operation operation Dehumidifier Air purifier Drying inside operation approx one hour Airflow Approx 30min Airflow stops compressor activates operating sound Compressor operates according to room temperatur...

Страница 12: ...akage 12 Using the OFF Timer The OFF timer can be set for each 2 4 8 hours Set the timer when the power is switched on Removing Water from the Tank The unit automatically shuts down and lights the Tank full lamp when the tank approximately 4L is full Empty the tank 7 4 3 2 Press Press No Display Low mode One press 2 is displayed Each consecutive press displays the following setting 2 4 8 To cancel...

Страница 13: ...e a minimum space of 20 cm behind the unit for attaching the hose Confirm that the hose does not show signs of deterioration such as cracks and clogging Inspect the hose every 2 weeks Insects or dirt blocking the hose may cause leakage resulting in malfunctions How to set up the drainage hose Correctly installed Incorrectly installed Necessary items Commercially available hose ID 15mm Long enough ...

Страница 14: ...can damage the unit or the water tank which may result in leakage Water tank Main unit Wipe with a soft cloth Floating element Do not remove or dismantle Do not remove the louvre front door Pre filter 1 Remove the front panel and pre filter 2 Remove the air purifying filter 5 Attach the pre filter and front panel 4 Fit the air purifying filter 3 Clean the pre filter Remove grit with vacuum cleaner...

Страница 15: ...g inside Performing drying inside to prevent mildew growth is recommended 2 Bundle power cord 3 Remove the drainage water Empty the water tank and wipe away any remaining drops of water 4 Clean the pre filter Remove grit with vacuum cleaner 5 Store the unit When you are sure that all parts of the unit are dry cover it with a cloth to keep it from dust Store the unit in an upright position in a pla...

Страница 16: ...struction Check to see if the pre filter is clogged Clean according to the maintenance procedures Check to see if the unit is in AUTO The unit is automatically controlling the dehumidifier fan and standby times Check to see if the water tank is full Empty the water tank and return it to its original position Check to see if the water tank is inserted properly Adjust the position of the water tank ...

Страница 17: ...s intermittently causing the sound to be heard occasionally The compressor does not activate after turning the unit off or for 3 minutes after plugging the unit into a power socket This is to protect the compressor from damage The heat converter heats rapidly causing a brief odour This is not a malfunction The moisture expelled from inside the unit may smell due to odorants that were not caught by...

Страница 18: ... Telephone number Date of purchase Day Month Year This symbol mark is for EU countries only This symbol mark is according to the directive 2002 96 EC Article 10 Information for users and Annex IV Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused This symbol means that electrical and electronic equipment at thei...

Отзывы: