28
3 SIGNALS AND WIRING
3.3 Explanation of power supply system
Connecting wires
■
Fabricating the wire insulator
Refer to the following for the stripped length of the wire insulator. Set the appropriate length based on the wire type and
fabrication condition.
Twist the core wires lightly and straighten them as follows.
A ferrule can also be used when connecting to the connectors. If using a ferrule, choose from one of the ferrules and the
crimping tools shown below.
Servo amplifier
Wire size
Ferrule model and its manufacturer
Crimping tool
For one wire
For two wires
MR-JET-10_ to MR-JET-
100_
AWG 16
AI 1,5 -8 BU
(Phoenix Contact)
A2
(DAIDO SOLDERLESS
TERMINAL MFG.)
CRIMPFOX-ZA3
(Phoenix Contact)
DS-H12
(DAIDO SOLDERLESS
TERMINAL MFG.)
PZ 6/5
(Nihon Weidmueller)
A2
(DAIDO SOLDERLESS
TERMINAL MFG.)
AWG 14
A2
(DAIDO SOLDERLESS
TERMINAL MFG.)
MR-JET-200_/ MR-JET-300_
AWG 16
AI 1,5 -10 BU
(Phoenix Contact)
AI-TWIN 2X 1,5 -10 BK
(Phoenix Contact)
AWG 14
AI 2,5 -10 BU
(Phoenix Contact)
AI-TWIN 2X 2,5 -10 BU
(Phoenix Contact)
H2.5/19D ZH
(Nihon Weidmueller)
AWG 12
AI 4 -10 GY
(Phoenix Contact)
H4.0/18D
(Nihon Weidmueller)
Insulator
Core
Stripped length
Loose and bent strands
Twist and straighten the strands.