26
3 SIGNALS AND WIRING
3.3 Explanation of power supply system
Power-on procedure
Signals such as output signals may be unstable at power-on.
Power-on procedure
1.
Connect a magnetic contactor between the power supply and the power supply (L1/L2/L3) of a servo amplifier by
referring to the following section. Switch off the magnetic contactor as soon as an alarm occurs.
Page 20 Example power circuit connections
2.
When the power supply is switched on, the servo amplifier will receive the servo-on command after 2.5 s to 3.5 s and
initial network communication.
Timing chart
ON
OFF
ON
OFF
ON
OFF
ON
OFF
100 ms
5 ms
100 ms
5 ms
10 ms
Power supply
Base circuit
Servo-on command
(from controller)
Servo-on (RD: ready)
ALM (Malfunction)
No alarm (ON)
Alarm
(OFF)
(2.5 s to 3.5 s and
initial network
communication)
Servo-on command received