3 SIGNALS AND WIRING
19
3
3
SIGNALS AND WIRING
Precautions
• Insulate the conductive parts of the terminals.
• If using a regenerative resistor, configure a circuit that shuts off the main circuit power supply with an alarm signal because
abnormal overheating of the regenerative resistor may cause smoke and fire.
• To prevent failure and malfunction, only the power supply/signal specified in the manual should be connected to a
corresponding terminal.
• To prevent unexpected operation of the servo motor, wire the equipment correctly and securely.
• Make sure to connect the cables and connectors by using the fixing screws and the locking mechanism. Failing to do so
may cause the cables and connectors to disconnect during operation.
• Unless stated otherwise, all connection diagrams in this manual are sink interface diagrams.
• Install a surge absorbing diode in the correct direction. Failing to do so may cause the amplifier to malfunction and not to
output signals, disabling protective circuits such as the emergency stop.
• If the wires are not properly secured to the terminal block, the poor contact may cause the wires and terminal block to
generate heat. Be sure to secure the wires with the specified torque.
• Connecting the servo motor for an incorrect axis to the power outputs (U/V/W) or CN2 of the servo amplifier may cause a
malfunction.
• Make sure that no operation signal is being input to the servo amplifier before resetting an alarm or releasing the
emergency stop. Failing to do so may cause an unexpected operation.
• If the power supply is shut off by a molded-case circuit breaker or a fuse, remove the cause and secure safety before
switching the power on.
• Install the servo amplifier according to the EMC guidelines because electromagnetic interference may affect the electronic
equipment used near the servo amplifier.
• To prevent an electric shock or a fire, do not disassemble, repair, or modify the product. Disassembled, repaired, and/or
modified products are not covered under warranty.
• Eliminate static electricity before performing actions such as wiring or operating a switch.
• When disconnecting the CNP1 connector from MR-JET-40_ to MR-JET-300_, do not forcibly pull the lead wires of the built-
in regenerative resistor or the CNP1 connector. Doing so may snap the lead wires of the built-in regenerative resistor.
• Before wiring, turn off the power and wait for 15 minutes or more until the charge light turns off. In addition, when confirming
whether the charge light is off or not, look at the light from the front of the servo amplifier.
DOCOM
RA
DOCOM
RA
Servo amplifier
Servo amplifier
24 V DC
24 V DC
Control output
signal
Control output
signal
For sink output interface
For source output interface