3 SIGNALS AND WIRING
3.3 Explanation of power supply system
27
3
Wiring CNP1
• For the wire sizes, refer to the following.
Page 83 Selection example of wires
• When wiring, remove the power connectors from the servo amplifier.
• Insert only one wire or ferrule into each wire insertion hole on each power connector.
Use the supplied servo amplifier power connector for wiring CNP1.
Connector
■
MR-JET-10_ to MR-JET-100_
■
MR-JET-200_/MR-JET-300_
Connector Receptacle assembly
Applicable wire
Stripped length
[mm]
Open tool
Manufacturer
Size
Insulator OD
CNP1
1-2349815-2
AWG 18 to 14
3.9 mm or less
8.5 ± 0.5
1981045-1
TE Connectivity
Connector Receptacle assembly
Applicable wire
Stripped length
[mm]
Open tool
Manufacturer
Size
Insulator OD
CNP1
1-2349825-8
AWG 16 to 10
4.7 mm or less
10.5 ± 0.5
2349891-1
TE Connectivity
CNP1
CNP1
Содержание Melservo-Jet MR-JET G-N1 Series