5 - 18
5. PARAMETERS
5.2 Detailed Description
5.2.1
Electronic gear
POINT
•
The guideline of the electronic gear setting range is
1
50
<
CMX
CDV
<
50. If the
set value is outside this range, noise may be generated during
acceleration/deceleration or operation may not be performed at the preset
speed and/or acceleration/deceleration time constants.
(1) Concept of electronic gear
The machine can be moved at any multiplication factor to input pulses.
CDV
CMX
=
4
No.
Parameter
3
No.
Parameter
Electronic gear
Parameters No. 3, 4
Encoder feedback pulse
CMX
CDV
Deviation
counter
Motor
Encoder
Inpu
t pu
ls
e tr
ai
n
+
−
The following setting examples are used to explain how to calculate the electronic gear:
(a) For motion in increments of 10
µ
m per pulse
Machine specifications
Ballscrew lead Pb =10 [mm]
Reduction ratio: n = 1/2
Servo motor resolution: Pt = 8192 [pulses/rev]
Servo motor
8192 [pulse/rev]
n
NM
NL
Pb=10[mm]
n=NL/NM
=1/2
CDV
CMX
=
∆
l
ο
x
S
Pt
∆
=
∆
l
ο
x
=
Pb
n
Pt
⋅
10
×
10
-3
x
10
2
1
8192
⋅
=
1000
16384
=
125
2048
Hence, set 2048 to CMX and 125 to CDV.
(b) Conveyor setting example
For rotation in increments of 0.01
°
per pulse
Machine specifications
Table resolution: 36000 pulses/rev
Reduction ratio: n = 4/64
Servo motor resolution: Pt = 8192 [pulses/rev]
Table
Timing belt : 4/64
Servo motor
8192 [pulse/rev]
CDV
CMX
=
S
Pt
∆
=
64
4
36000
Pt
×
=
36000
131072
=
1125
4096
Reduce CDV to 32767 or less and round off the result to the units.