3 - 43
3. SIGNALS AND WIRING
3.8 Servo Motor with Electromagnetic Brake
(1) Setting
Using parameter No.33 (electromagnetic brake sequence output), set a time delay from electromagnetic
brake operation to base circuit shut-off as in the timing chart shown in (2) in this section.
(2) Operation timing
(a) Servo on signal command (from controller) ON/OFF
Tb after the servo-on signal is switched off, the base circuit is shut off and the servo motor coasts.
The following chart shows the way of holding the motor shaft in vertical lift applications.
・
Adjust Tb (parameter No. 33) to minimize a drop after the servo-on signal is switched off.
・
Switch off the servo-on signal after the servo motor has stopped.
Servo motor speed
Electromagnetic
brake (CNP2-9)
ON
OFF
Base circuit
Invalid(ON)
Valid(OFF)
ON
OFF
Servo-on(SON)
Electromagnetic brake
operation delay time(10ms)
Tb
Coasting
0 r/min
(60ms)
(80ms)
(b) Emergency stop signal (EMG) ON/OFF
Electromagnetic brake
operation delay time
(10ms)
Dynamic brake
Dynamic brake
Electromagnetic brake
Servo motor speed
Electromagnetic
brake(CNP2-9)
ON
OFF
Base circuit
Invalid(ON)
Valid(OFF)
Invalid(ON)
Valid(OFF)
Electromagnetic
brake
Electromagnetic brake release
Forced stop(EMG)
(180ms)
(180ms)