24
5 CONNECTION EXAMPLE FOR EMC COUNTERMEASURES
5.1 For 1-axis with 22 kW or less
5
CONNECTION EXAMPLE FOR EMC
COUNTERMEASURES
5.1
For 1-axis with 22 kW or less
*1
: Specific EMC countermeasure
*2
: Shielded cable
*3
: Shielded cable or metal conduit
*4 When the control circuit power supply (L11/L21) of the servo amplifier is 24 V DC, connect AC/DC power supply.
*5 Page 8 Cabinet design
*6 Page 13 Servo motor power cable (1)
*7 Page 15 Encoder cable (2)
*8 Page 16 If controller and servo amplifier are in the same cabinet
*9 Page 16 If controller or others is in the different cabinet from servo amplifier
*10 Page 17 Cables in the same cabinet (4)
*11 Page 17 Regenerative option connection cable (5)
*12 Page 18 Noise filter (for controller power supply)
*13 Page 18 EMC filter (for servo amplifier power supply)
*14 Page 20 Cable clamp fitting
*2
*1
*2
*1
*2
*2
L1/L2/L3
L11/L21
P/C
U/V/W/
*2
*3
( )
E
E
*1
*1
1-axis
Servo amplifier
Cable clamp:
*10*14
Cabinet:
*5
Surge
protector
EMC
filter:
*13
Magnetic
contactor
24 V DC
Option
Controller,
etc.
Controller
Noise
filter:
*12
Regenerative
option
Cable clamp:
*8*14
Cable clamp:
*11*14
Cable clamp:
*9*14
Cabinet:
*5
Cable clamp:
*11*14
Encoder
Cable clamp:
*7*14
Cable clamp:
*6*14
U/V/W
Servo motor
*1
*1
*1
*1
*1
*1
*1
Molded-case
circuit
breaker
Содержание MELSERVO EMC
Страница 1: ...EMC Installation Guidelines Mitsubishi Electric AC Servo System ...
Страница 2: ......
Страница 6: ...4 1 INTRODUCTION MEMO ...
Страница 8: ...6 2 EMC STANDARDS MEMO ...
Страница 43: ......