10
3 EMC COUNTERMEASURES
3.3 Filter wiring and installation
3.3
Filter wiring and installation
When connecting multiple servo amplifiers to one EMC filter, refer to the following.
Page 32 Connecting multiple servo amplifiers to one EMC filter
Wiring
Wire the servo and filter as shown below.
Separate the EMC filter input cable and output cable as far as possible. If they are too close, the noise generated from the
output cable is induced into the input cable, and the filter is not effective. Separate the cables by at least 30 cm if possible.
Servo
motor
Power
supply
Magnetic
contactor
Servo amplifier
Control circuit
power supply
Main circuit
power supply
Wiring length 1.5m or less (recommended)
Molded-
case
circuit
breaker
EMC
filter
EMC
filter
Output (servo amplifier side)
Input (power supply side)
Separate the cables by at least 30 cm.