3 EMC COUNTERMEASURES
3.4 Cable layout
3.4
Cable layout
Securely ground the cabinets 1 and 2 and the servo motor.
Separate the main circuit power cable of the servo amplifier, power cable of the servo motor, and control circuit signal cable by
30 cm or more, and do not wire them in parallel or bundle them.
An installation example is shown in the figure below.
Each cabling method is described separately.
(1)
(2)
(7)
(4)
(3)
(3)
Servo motor
Encoder
Servo amplifier
Controller
Power supply
EMC filter
Controller, etc.
Cabinet 2
Cabinet 1
Magnetic contactor
Option
Surge protector
24 V DC
power supply