5 - 66
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Item Setting
details
Setting value
1
00: Not used
01: 1125[Hz]
02: 563[Hz]
03: 375[Hz]
04: 282[Hz]
05: 225[Hz]
06: 188[Hz]
07: 161[Hz]
00: Invalid 08: 141[Hz]
01: 1125[Hz] 09: 125[Hz]
02: 563[Hz] 10: 113[Hz]
03: 375[Hz] 11: 102[Hz]
04: 282[Hz] 12: 94[Hz]
05: 563[Hz] 13: 87[Hz]
06: 375[Hz] 14: 80[Hz]
07: 282[Hz] 15: 75[Hz]
00: Invalid 10: 281.3[Hz]
01: 4500[Hz] 11: 264.7[Hz]
02: 2250[Hz] 12: 250[Hz]
03: 1500[Hz] 13: 236.8[Hz]
04: 1125[Hz] 14: 225[Hz]
05: 900[Hz] 15: 214.3[Hz]
06: 750[Hz] 16: 204.5[Hz]
07: 642.9[Hz] 17: 195.7[Hz]
08: 562.5[Hz] 18: 187.5[Hz]
09: 500[Hz] 19: 180[Hz]
0A: 450[Hz] 1A: 173.1[Hz]
0B: 409.1[Hz] 1B: 166.7[Hz]
0C: 375[Hz] 1C: 160.1[Hz]
0D: 346.2[Hz] 1D: 155.2[Hz]
0E: 321.4[Hz] 1E: 150[Hz]
Notch filter selection
0F: 300[Hz] 1F: 145.2[Hz]
Pr.118
M
a
c
h
ine res
onanc
e s
uppres
s
ion f
ilt
er
Notch depth selection
Used to set the notch frequency to match the
response frequency of the mechanical system.
0: Deep (-40db)
1:
(-14db)
2:
(-8db)
3: Shallow (-4db)
S
e
rvo adj
us
tm
ent
param
et
ers
Pr.119
Feed forward gain
Used to set the feed forward gain for position control.
Set "100" to nearly zero the droop pulse value when
operation is performed at constant speed.
Note that sudden acceleration/deceleration will
increase overshoot.
POINT
Be sure to set up this parameter "2: Invalid (No auto
tuning) when you set up Pr.108 Auto tuning.
0 to 100[%]
Содержание MELSEC-Q QD75M
Страница 1: ...MELSEC Q QD75M Positioning Module User s Manual Details QD75M1 QD75M2 QD75M4 ...
Страница 17: ...MEMO ...
Страница 64: ...3 11 MELSEC Q 3 SPECIFICATIONS AND FUNCTIONS MEMO ...
Страница 91: ...4 16 MELSEC Q 4 INSTALLATION WIRING AND MAINTENANCE OF THE PRODUCT MEMO ...
Страница 108: ...5 17 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 112: ...5 21 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 116: ...5 25 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 138: ...5 47 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 182: ...5 91 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 188: ...5 97 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 194: ...5 103 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 253: ...5 162 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 274: ...6 21 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 275: ...6 22 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 276: ...6 23 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 277: ...6 24 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 278: ...6 25 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 279: ...6 26 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 280: ...6 27 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 281: ...6 28 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 282: ...6 29 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 283: ...6 30 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 284: ...6 31 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 285: ...6 32 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 286: ...6 33 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 287: ...6 34 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 288: ...6 35 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 289: ...6 36 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 290: ...6 37 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 291: ...6 38 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 292: ...6 39 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 293: ...6 40 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 294: ...6 41 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 295: ...6 42 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 296: ...6 43 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 297: ...6 44 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 298: ...6 45 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 299: ...6 46 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 300: ...6 47 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 301: ...6 48 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 302: ...6 49 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 303: ...6 50 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 304: ...6 51 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 305: ...6 52 MELSEC Q 6 PLC PROGRAM USED FOR POSITIONING CONTROL ...
Страница 332: ...7 7 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO ...
Страница 336: ...7 11 MELSEC Q 7 MEMORY CONFIGURATION AND DATA PROCESS MEMO ...
Страница 347: ...MEMO ...
Страница 477: ...9 116 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 539: ...11 36 MELSEC Q 11 MANUAL CONTROL MEMO ...
Страница 663: ...14 18 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 771: ...Appendix 2 MELSEC Q APPENDICES MEMO ...
Страница 845: ...Appendix 76 MELSEC Q APPENDICES MEMO ...
Страница 855: ...Index 10 X X0 QD75 READY 3 15 X1 Synchronization flag 3 15 Z Zero speed Pr 130 5 74 ...