Appendix 2 How to Replace an Existing Product
■
Device types for accessing CC-Link IE Field Network modules
*1 The own station direct link special relay (SB) has three device type definitions; DevSM, DevQSB, and DevLSB(0). Any of them can be
specified for the same operation.
*2 The own station direct link special register (SW) has three device type definitions; DevSD, DevQSW, and DevLSW(0). Any of them can
be specified for the same operation.
Alternative method
■
Refreshing device
■
Module access device
*1 For details on the buffer memory address to which link devices are assigned, refer to the manual for the network module to be accessed.
■
CCPU_ReadLinkDevice/CCPU_WriteLinkDevice
• Access the own station link device of a network module by using the CCPU_ReadLinkDevice/CCPU_WriteLinkDevice
function. For details, refer to the relevant functions.
Page 90 CCPU_ReadLinkDevice,Page 118 CCPU_WriteLinkDevice
Device type deleted from R12CCPU-V
Alternative method
Device
Device name specification
Own station remote input
RX
DevLX(0)
The area (device) corresponding to the device type deleted from
R12CCPU-V can be accessed with either of the methods below.
Page 192 Refreshing device, The access target is a network
module on the own station.
Page 192 Module access device, The access target is a network
module on the own station.
Page 192 CCPU_ReadLinkDevice/CCPU_WriteLinkDevice
Own station remote output
RY
DevLY(0)
Own station remote register (for
sending)
RWw
DevLW(0)
Own station remote register (for
receiving)
RWr
Own station direct link special relay
SB
DevSM, DevQSB, DevLSB(0)
The area (device) corresponding to the device type deleted from
R12CCPU-V can be accessed with either of the methods below.
Page 192 Refreshing device, The access target is a network
module on the own station.
Page 192 CCPU_ReadLinkDevice/CCPU_WriteLinkDevice
Own station direct link special
register
SW
DevSD, DevQSW, DevLSW(0)
Buffer memory
DevSPB
The area (device) corresponding to the device type deleted from
R12CCPU-V can be accessed with the following method.
Page 192 Module access device, The access target is a network
module on the own station.
Access target
Alternative method
The access target is a network module on the own
station.
Configure the refresh setting so that a device of C Controller module, M, B, D, W, or ZR is refreshed by
a link device of a network module.
Use the MELSEC data link functions to access a device of C Controller module, M, B, D, W or ZR.
The access target is a network module on the other
station.
Configure the refresh setting for CPU module on the other station so that a device of C Controller
module on the other station is refreshed by a link device of a network module.
Specify the other station to the network number and station number in the MELSEC data link functions
to access a device of CPU module on the other station.
Access target
Alternative method
The access target is a network module on the own
station.
Open a communication line by specifying 'bus interface' to the channel in the mdOpen function.
Specify the module access device (DevSPG) to the device type in the MELSEC data link functions, and
access the area to which link devices are assigned
in the buffer memory of a network module.
The access target is a network module on the other
station.
Open a communication line by specifying the channel name corresponding to each network to the
channel in the mdOpen function.
Specify the other station to the network number and station number in the MELSEC data link functions.
Specify the module access device (DevSPG) to the device type in the MELSEC data link functions, and
access the area to which link devices are assigned
in the buffer memory of a network module.
Содержание MELSEC iQ-R C
Страница 1: ...MELSEC iQ R C Controller Module Programming Manual ...
Страница 2: ......
Страница 201: ...I 199 MEMO ...
Страница 203: ...I 201 MEMO ...
Страница 207: ......