5 INSTALLATION
5.1 Installation Location
63
5
Configuration in 2 stages with extended extension cable
Layout in enclosure
The PLC components can be laid out in one stage or in two stages, upper and lower. The connecting procedures in each case
are explained below.
Keep a space of at least 50 mm between the module main body or other devices and structure.
Also, separate the PLC from high-voltage lines, high-voltage devices, and power devices when possible. Failure to do so may
cause fire, equipment failures or malfunctions.
Configuration in 1-stage layout
Configuration in 2-stage layout
*1 Including FX5-1PSU-5V
Another
equipment
Powered
input/output
module
Extended
extension cable
Another
equipment
Another
equipment
A
A
A
A
A
A
A
A
FX5-20PG-P
•
FX5-30EC
•
FX5-65EC
FX5UJ
CPU module
FX5-16EX/ES
FX5-16EYT/ES
FX5-16EYT/ES
FX5-16EYT/ES
FX5-232ADP
50mm
FX5-CNV-BC
FX5-4AD
Extension module
A
≥
50 mm
A
A
FX5UJ
CPU module
Intelligent
function module
For product dimensions or manual for various
products, refer to
App 3 I/O Module.
Expansion
adapter
Output
module
Input
module
50mm
FX5UJ
CPU module
Intelligent
module
For product dimensions or manual for various
products, refer to
App 3 I/O Module.
For product dimensions or manual for various
products, refer to
App 3 I/O Module.
Input module
Output module
Powered
input/output
module
Intelligent
module
Input module
Output module
Expansion
adapters
Extended
extension cable
• FX5-30EC (30cm)
• FX5-65EC (65cm)
Extension module
*1