CHAPTER 6
CONNECTION OF REMOTE I/O UNIT
6.1 Outline of Remote I/O Unit
73
CHAPTER 6 CONNECTION OF REMOTE I/O UNIT
This chapter describes the connection of the remote I/O unit and machine control signals.
6.1 Outline of Remote I/O Unit
The following eight types of signals can be input/output from the remote I/O unit (FCUA-DX
)
according to the type and No. of contacts. Use serial link connections (MC link B) to connect the unit with
the control unit or the communication terminal.
When the remote I/O unit is connected with serial links, multiple units can be used as long as the total No.
of occupied channels is within 8 channels. (Refer to "Section 6.14 Setting the Channel No. for
Connecting Multiple Remote I/O Units" for details.)
Unit name
Machine control signals that can be handled
No. of occupied
serial link channels
FCUA-DX100
Digital input signal (DI)
: 32 points (photo coupler insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) sink type
1
FCUA-DX101
Digital input signal (DI)
: 32 points (photo coupler insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) source type
1
FCUA-DX110
Digital input signal (DI)
: 64 points (photo coupler insulation) sink/source type
Digital output signal (DO) : 48 points (non-insulation) sink type
2
FCUA-DX111
Digital input signal (DI)
: F64 points (photo coupler insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) source type
2
FCUA-DX120
Digital input signal (DI)
: 64 points (photo coupler insulation) sink/source type
Digital output signal (DO) : 48 points (non-insulation) sink type
Analog output (AO)
: 1 point
2
FCUA-DX121
Digital input signal (DI)
: 64 points (photo coupler insulation) sink/source type
Digital output signal (DO) : 48 points (non-insulation) source type
Analog output (AO)
: 1 point
2
FCUA-DX130
Digital input signal (DI)
: 32 points (photo coupler insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) sink type
Handle input (AO)
: 2 pieces
2
FCUA-DX131
Digital input signal (DI)
: 32 points (photo coupler insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) source type
Handle input (AO)
: 2 pieces
2
FCUA-DX140
Digital input signal (DI)
: 32 points (photo coupler insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) sink type
Analog input (AI)
: 4 points
Analog output (AO)
: 1 point
2
FCUA-DX141
Digital input signal (DI)
: 32 points (photo coupler insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) source type
Analog input (AI)
: 4 points
Analog output (AO)
: 1 point
2