APPENDIX 3 EMC INSTALLATION GUIDELINES
5. Measures for Wiring in Panel
128
(3) Remote I/O cable [FCUA-R211 cable]
Shield clamp
Remote I/O unit
Fer ri te c or e
FCUA
-
R2 11 cable
Base I/O unit
•
Use a shield clamp within 10cm from the panel's inlet/outlet.
•
Install a ferrite core on both ends of the connected units.
•
The shield clamp is not required if the control unit and base I/O unit are wired in the same
panel.
(4) Servo communication cable [SH21/FCUA-R000 cable]
Shield clamp
Fer rite c or e
Base I/O unit
Drive section unit
SH21 cable
Drive section unit
FCUA- R000 cable
•
Use a shield clamp within 10cm from the panel's inlet/outlet.
•
Install a ferrite core on both ends of the connected units.
•
The shield clamp is not required if the base I/O unit and drive section unit are wired in the
same panel.
CAUTION
CAUTION
Control panel
Operation panel
Control panel
Control panel