CHAPTER 5 CONNECTION OF I/O INTERFACE
5.4 Scan I/O
72
(6) Digital output (CF33)
The HR347 output circuit is a sink type (sink output), and the HR357 output circuit is a source type
(source output).
+24V
RA
R
PL
G N D
HR357
G N D
+24V
HR347
RA
R
PL
G N D
Sink type
Source type
Cont rol
circ u it
Cont rol
circ u it
(Machine side)
(Machine side)
CF33
CF33
Output conditions
Insulation method
Non-insulation
Rated load voltage
DC+24V
Max. output current
60mA/point
Saturation voltage
1.6V (standard)
Output delay time
40
µ
s
Do not apply voltages other than those indicated in this manual on the connector. Doing
so may lead to destruction or damage.
∗
When using an inductive load such as relays, always connect a diode (withstand voltage
100V or more, 100mA or more) in parallel to the load as a noise measure.
∗
When using a capacitive load such as a lamp, always connect a protective resistor
(R=150
Ω
) serially to the load to suppress rush currents. (Make sure that the current,
including the instantaneous current, is less than the above tolerable current.)
CAUTION