![Mitsubishi Electric MELDAS 600 Series Скачать руководство пользователя страница 132](http://html.mh-extra.com/html/mitsubishi-electric/meldas-600-series/meldas-600-series_connection-manual_238536132.webp)
APPENDIX 3 EMC INSTALLATION GUIDELINES
5. Measures for Wiring in Panel
126
(2) Example of grounding connection for M6
0 Series
Mai n grou ndi ng plate
of distribution panel
R220 cable
(24VDC cable)
0V
Short bar
FG cable
200VAC input
FCU6 - DX
Base I/O unit
FG cable
AC input
Stabili zed
power supply
SH21 cable
(
f or NC AMP
)
F010 cable
0
0
CF31 CF32
CF34
CF33
SV2
SV1
HR3□□
RI O1
RI O2
DC IN
C F 1 0
E N C
C R 3 1
SK I P
0
J2
CF11
CF12
CON1
CF21
CF22
K/B
MOUSE
HANDLE
RIO3
Control unit
F CU6 - M U
Display unit
F CU6 - D U
NC keyboard
FCU6- KB
FG cable
FG cable
FG cable
FG cable
R220 cable
(24VDC cable)
24
VD
C
(+)
FG
Operation panel
Control panel