APPENDIX 1 INSTALLATION DIMENSIONS
Appendix 1.14 Grounding Plate and Clamp Fitting Outline Drawings
105
Appendix 1.14 Grounding Plate and Clamp Fitting Outline Drawings
The shield wire generally only needs to
be grounded to the connector's case
frame. However, the effect can be
improved by directly grounding to the
grounding plate as shown on the right.
Install the grounding plate near each
unit. Peel part of the cable sheath as
shown on the right to expose the shield
sheath. Press that section against the
grounding plate with the clamp fitting.
Note that if the cable is thin, several
can be clamped together.
Install the grounding plate directly onto
the cabinet or connect a grounding
wire so that sufficient frame grounding
is achieved.
If the AERSBAN-SET, containing the
grounding plate and clamp fitting, is
required, please contact Mitsubishi.
• Outline drawing
11
35
6
22
35
A
C
24
17.5
6
3
7
B
±
0.
3
2-
φ
5 hole
Installation hole
Note 1)
M4 sc rew
0 -0
.0
2
MAX L
10
24
30
0
+0
.3
Note 1)
Screw hole for wiring to cabinet's grounding plate
Note 2)
The grounding plate thickness is 1.6mm
A B C Enclosed
fittings
L
AERSBAN-DSET
100
86
30
Two clamp fittings A
Clamp fitting A
70
AERSBAN-ESET 70 56
−
One clamp fitting B
Clamp fitting B
45
40
Cable
Clamp f it ting
(F it ting A, B)
Grounding plate
Shield sheath
Clamp section drawing
Grounding plate
Clamp fitting