CHAPTER 4 SYSTEM CONNECTION
4.1 General System Diagram
17
CHAPTER 4 SYSTEM CONNECTION
4.1 General System Diagram
4.1.1 M615/M635
OFF
ON
CF01
CF24
CF25
DCOUT
ON/OFF
CF22
F171
F172
HR292
/293
F030/F031
CF11 CF12
F050
F060
F149
CF13
F140
T2
T3
PE
MR-J2-□CT
L11
L21
L+
MDS-B -SV
/
MDS-B -SP
Converter
L2
L3
L11
L21
B-AL
R
R
RIO
CF10
CF31
CF32
CF33
CF34
ENC1
SKIP
SV1 SV2
RIO1 RIO2
F0 7 0
FCU6-DX***
FCUA-R211
(SH41)
24VDC
DX1**
QY231
J 4
CSH41A
DCIN
RIO1RIO2
FCUA-R211
(SH41)
R
R
F040/F041
R301
DI
DI
DO
DO
R301
R301
R301
24VDC
DCIN
L1
2 4 V D C
FDD
F130
FCU6-DUN31/DUC32/DUT31
F090
MOUSE2
PARALLEL
CF14
F110
F120
F010
F250
FCU6-MU5**
(M615/M635)
CF11 CF12
HD
ISP
HD
CF14
CFD
LCD
CF01 DCIN
EMG CF10
EMG
CSH41B
Display unit
RS-232-C
device
HDD unit
Control unit
Heater power cable
Base I/O unit
Remote I/O card
Machine control relay/contact
MC link B
Terminator
R-TM
To next remote I/O unit
Electric cabinet
Synchronous feed encoder
Sensor contact
Max. 8 points
Servo amplifier
Machine control relay/contact
Remote I/O unit
AC reactor
(Note 3)
(Note 4)
(Note 5)
(Note 5)
NC axis
amplifier
spindle
Wire spliting PCB
K B
MOUSE
DCIN
(HEATR)
DCIN
(PD25A)
POS
RIO3
CON1
HANDLE
CF21
F070
24VDC
F110
F070
24VDC
F020/F021/F022
F030/F031
R
R
DX1**/HR357
DCIN
RIO1 RIO2
FCUA-R211
(SH41)
FCUA-R211
(SH41)
FCU6-KB004/KB014
PD25A
DCOUT
ON/OFF
ACIN
NFB
FG
MC
MC
CN1A
CN1B
L11
L21
L1
L2
L3
L-
CN1A
CN4
CN1B
L+
L-
MC1
CN4
24VDC
F 0 7 0
NFB
S
R
T
RA
FG
FCUA-R211
(SH41)
FCUA-R211
(SH41)
Manual pulse generator
(FCUA-HD60)
Terminator
R-TM
P-OFF signal
NC keyboard
24VDC(+)
stabilize d
power supply
OT release switch
MC link B
Terminator
R-TM
To next remote I/O unit
External power
supply unit
No fuse breaker(NFB)
3-phase 200V
〜
230VAC
Remote I/O unit
To next remote I/O unit
Machine control relay/contact
(Note 1)
(Note 6)
(Note 2)
(Note 5)
(Note 5)
(Note 5)
(Note 5)
(Note 1)
Refer to "Section 4.3.1 (2)" when not using the PD25A power supply.
(Note 2)
After connecting the DO output selected by the user and the application software running on Windows has ended, turn
the external power supply unit's power OFF with the DO output.
(Note 3)
Connect the F149 cable pin 8 side [HD ISP] connection to the ISP terminal at the side of CF12.
The target units are only FCU6-MU501 to FCU6-MU514. This is not used by the other units.
(Note 4)
CF14 is used only for FCU6-MU515/516. This is not used by the other units.
(Note 5)
Normally, use the FCUA-R211 cable for the RIO cable.
If the cable length is short due to bridging between units in the same panel, the SH41 cable can be used.
(Note 6)
The DCIN (HEATER) connector is not used with FCU6-KB014.