Specifications
2
.
Applicable Standards
Electromagnetic Compatibility
Emissions
Radiated Emission
EN61326-1/CISPR 11
,
FCC Part15 Subpart B Class A
Conducted Emission
EN61326-1/CISPR 11
FCC Part15 Subpart B Class A
Harmonics Measurement
EN61000-3-2
Flicker Meter Measurement
EN61000-3-3
Immunity
Electrostatic discharge Immunity
EN61326-1/EN61000-4-2
Radio Frequency Electromagnetic field Immunity
EN61326-1/EN61000-4-3
Electrical Fast Transient/Burst Immunity
EN61326-1/EN61000-4-4
Surge Immunity
EN61326-1/EN61000-4-5
Conducted Disturbances, Induced By Radio Frequency Fields Immunity
EN61326-1/EN61000-4-6
Power Frequency Magnetic Field Immunity
EN61326-1/EN61000-4-8
Voltage Dips and Short Interruptions
EN61326-1/EN61000-4-11
Safety
Europe
CE, as per EN61010-1
U.S. and Canada
cRUus as per UL61010-1, IEC61010-1
Installation Category
Ⅲ
Measuring Category
Ⅲ
Pollution Degree
2
3. Precautions for MODBUS
®
RTU Communication
Item
Specifications
Physical interface
RS
-
485 2wires half duplex
Protocol
RTU (Binary data)
Synchronization method
Start-stop synchronization
Network topology
Daisy-chain
Baud rate
2400, 4800, 9600, 19200, 38400bps
Data bit
8
Stop bit
1, 2
Parity
Odd, Even, None
Slave address
1 to 255 (0
:
For broadcast)
Distance
1200m
Maximum Number
31
Response time
1s or less (time to a response after receiving a query)
Terminate
120Ω
1/2W
Recommended cable
Shielded twisted pair, AWG24 to 14 gauge
About Programming
In addition to this manual, read the following documents too.
Electronic Multi-Measuring Instrument ME96NSR-MB/ ME96SSH-MB/ ME96SSR-MB/ ME96SSE-MB Interface
specifications ........................................................................................................................................................ LSPM-0075
4. Precautions for CC-Link Communication
Item
Specifications
CC-Link station type
Remote device station (ver.1 remote device station or ver.2 remote device station)
Number of occupied stations
Ver.1 remote device station (ver.1 compatible slave station) setting: 1 station
Ver.2 remote device station (ver.2 compatible slave station) setting: 1 station (Expanded
cyclic setting: Octuple)
CC-Link version
CC-Link Ver 1.10 / 2.00
Transmission speed
Can select from 156kbps / 625kbps / 2.5Mbps / 5Mbps / 10Mbps
Maximum number of connected
stations
If the system is configured by only this instrument, up to 42 units can be connected.
(note1)
Note1: As for details, refer to the following manuals.
Manual Name
Manual Number
(Model Code)
CC-Link System Master/Local Module User’s Manual type QJ61BT11N Describes the system
configuration, performance specifications, functions, handling, wiring and troubleshooting of the
QJ61BT11N. (Optionally available)
SH-080394E
(13JR64)
CC-Link Dedicated Cable
Use the CC-Link dedicated cables for the CC-Link system. If a cable other than the CC-Link dedicated cable is used, the
performance of the CC-Link system cannot be guaranteed.
For the specifications of the CC-Link dedicated cables or any other inquiries, visit the following website:
CC-Link Partner Association:
REMARK
For details, refer to the CC-Link cable wiring manual issued by CC-Link Partner Association.
About Programming
In addition to this manual, read the following documents too.
Electronic Multi-Measuring Instrument programming manual (CC-Link) .............................................................. LEN080334
Electronic Multi-Measuring Instrument programming manual (CC-Link)(For ver. 2 remote device station) ......... LEN130391