- 16 -
3. Setting
3.2 Setting menu 1: Basic Settings (Setting the Phase Wire System, Display Pattern, VT/Direct Voltage,
CT Primary Current, etc.)
Set the VT
When direct input (without VT)
⇒
Select no, and then press , shift to following (1).
When using VT
⇒
Select yES, and then press , shift to following (2)
1.
For 3-phase 4-wire
2. For
3-phase 3-wire or 1-phase 2-wire
Note. VT is voltage transformers.
(1)
For direct input (without VT)Set the direct voltage.
(
a
)
For 3-phase 4-wire
(phase to neutral voltage / phase to phase voltage)
(
b
)
For 3-phase 3-wire (2CT, 3CT) or 1-phase 2-wire
(
c
)
For 1-phase 3-wire
(
1N2, 1N3
)
(phase to neutral voltage / phase to phase voltage)
③
VT / direct voltage
<When
①
phase wire system is set to 1-phase 3-wire>
Use only for direct input. This setting will be skipped.
SET
SET
110V
220V
440V
yES
no
110/220V
220/440V
no
yES
63.5/110V
100/173V
110/190V
220/380V
240/415V
254/440V
277/480V
SET
DISPLAY
(
2
)
For other phase wire system except 3-phase 4-wire
D
is
pl
ay
P
at
ter
n
C
ur
rent
C
ur
rent
D
ema
nd
V
ol
tag
e
A
c
ti
v
e P
ow
er
P
ow
er
F
ac
tor
R
eac
ti
v
e
P
ow
er
F
requenc
y
A
c
ti
v
e E
ner
gy
(I
m
por
te
d
)
A
c
ti
v
e E
ner
gy
(E
x
p
or
ted)
R
eac
ti
v
e
E
n
er
gy
y
(I
mpor
te
d
L
AG
)
Additional display
A
c
ti
v
e
E
ner
gy
(
Impor
ted
)
Ac
ti
v
e
En
e
rgy
(E
x
p
or
ted)
R
eac
ti
v
e E
n
er
gy
(S
pec
ial
)
P
er
iodi
c
Ac
ti
v
e E
n
er
gy
R
ol
lin
g D
e
ma
nd
H
ar
mon
ic
C
ur
ren
t/
V
ol
tag
e
D
ig
it
a
l I
n
p
u
t/
O
ut
pu
t
O
per
at
ion t
im
e
P01
○
○
○
○
△
△
△
△
△
P02
○
○
○
○
○
○
△
△
△
△
△
△
P03
○
○
○
○
○
○
△
△
△
△
△
P04
○
○
○
○
○
○
○
○
○
△
△
△
△
△
△
△
P05
○
○
○
○
△
△
△
△
△
P06
○
○
△
△
△
△
△
P07
○
○
○
△
△
△
△
△
P08
○
○
○
○
○
△
△
△
△
△
△
P09
○
○
○
△
△
△
△
△
P10
○
○
○
○
△
△
△
△
△
P11
○
○
○
○
○
△
△
△
△
△
△
P12
○
○
○
○
○
○
△
△
△
△
△
△
P13
○
○
○
○
○
○
○
○
○
△
△
△
△
△
△
△
P00
□
□
□
□
□
□
□
□
□
□
△
△
△
△
△
△
△
△
Note: The following settings are required for displaying elements on an additional display.
Measurement element on additional
display
Setting item
Reference
Pages
Active energy
Exported
/reactive
energy Special(*)
Setting Menu 3 Active energy measurement
Page 22
Harmonic current/ Harmonic voltage
Setting Menu 3 Harmonics display
Page 22
Periodic Active Energy
Setting Menu 7 Periodic Active energy display
Page 32
Rolling Demand
Setting Menu 7 Rolling demand display
Page 32
Digital input / output status
Setting Menu 7 Digital input / output display
Page 33
Operation time
Setting Menu 8 Operation time display
Page 34
※
When display elements does not set active energy/ reactive energy, ’P00’ of active energy/ reactive
energy on additional display does not appear.