- 8 -
FUNCTION MENU (SETTING MENU ONLY FOR SERVICE)
Displaying the FUNCTION menu
1. Select “LANGUAGE” in the FEATURE menu.
2. Press the [AUTO POSITION], [ENTER], and [AUTO POSITION] buttons on the remote control in order. The FUNCTION
menu will be displayed.
Exiting the FUNCTION menu
Press the [MENU] button while the FUNCTION menu is displayed.
Note: The menu is not initialized by selecting “RESET ALL” in the FEATURE menu. To initialize the menu, press the [MENU],
[ENTER], and [
] buttons of the projector at the same time.
Item
Setting range
Function
Default
setting
Last
memory
UNIFORMITY
ON, OFF
To demonstrate the effect of color
uniformity correction.
OFF: Without correction
ON: With correction
ON
No
Y/C DELAY
±3
To adjust the amount of DELAY of Y and C of
the VIDEO signal (which is input to the
S-VIDEO and VIDEO terminal).
Max.=+111nsec
Min.=-111nsec
(every 37 ns)
0
Yes
MODE DISPLAY
ON, OFF
To select whether or not to indicate the
switched input terminal in the upper right-hand
corner of the screen at the time of switching
the input terminal while the power is on.
ON: With indication
OFF: Without indication
ON
Yes
REMOTE POS.
AUTO, FRONT,
REAR
To select the remote control sensor
to be enabled.
AUTO: Both of FRONT and REAR sensors
FRONT: Front sensor only
REAR: Rear sensor only
AUTO
Yes
DIGITAL CABLE
DEFAULT(0-15m),
2-25m, 20-25m,
25-35m
To select the length of the DVI cable
for the digital connection.
DEFAULT: (0-15m)
2-25m:
20-25m:
25-35m:
DEFAULT
(0-15m)
Yes
LAMP
WARNING 1
1 MIN, NO LIMIT
To set the time over which the alert
for the lamp replacement is dis-
played.
1 MIN: 1 minute
NO LIMIT: No time limit (After the
alert is displayed for one minute,
you can cancel it by any button or
the RS-232C command.)
1 MIN
Yes
LAMP
WARNING 2
NORMAL,
AFTER P-ON
Set the display mode of warning the
lamp exchange.
Normal:
display when power on
and after 3800hours on
each 20 hours
After P-ON:
displays only after P-ON
NORMAL
Yes
TEST SIGNAL
WHITE,BLACK,
CROSSHATCH,
RED,GREEN,
BLUE,YELLOW,
CYAN,MAGENTA
To display the test patterns.
(The ENTER button displays the test
pattern. Pressing any button cancels
the displayed test pattern.)
OFF
No
Содержание LC62 CHASSIS XL6500LU
Страница 22: ... 4 PCB LOCATION Fig 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Страница 108: ... MEMO ...
Страница 119: ...P XL 00LU XL 00U ...
Страница 123: ...P XL 00LU XL 00U ...
Страница 130: ...P 12 XL 00LU XL 00U ...