- 2 -
Adjustment with Microsoft
®
Windows
®
95/98/Me/XP Operating System
1. Starting
1. Start
Windows
®
95/98/Me/XP.
2. Select [Start] - [Programs] - [Accessories] - [Communications] - [Hyper Terminal] in order.
The [Connection Description] window will open.
Note: You can select [Start] - [Programs] - [Accessories] - [Hyper Terminal] in order and double-click [hypertrm.exe] in Windows
®
95.
2. Hyper Terminal Setting
1. Make settings on the [Connection Descrip-
tion] window referring to the table on the
right.
Item
Setting
Connection
Port (COM1-COM4)
Port settings
: Bits per second
: Data bits
:
Parity
: Stop bits
:
Flow
9600
8
None
1
control
Settings : Emulation
VT100
ASCII setup
: ASCII Sending
:
ASCII
Receiving
Send line ends with line feeds
Echo typed characters locally
Line delay
: 1000 milliseconds
Character delay : 10 milliseconds
Append line feeds to incoming line ends
3. Adjustment
Type the adjustment command and the adjustment value on the Hyper Terminal window in capital alphanumeric letters, and
press the [ENTER] key.
4. Writing Adjustment Value
Type the adjustment command and the adjustment value on the Hyper Terminal window in capital alphanumeric letters, and
press the [ENTER] key.
Note:
This step is not necessary for “ADC offset/gain adjustment,” which is carried out automatically.
5. Closing
Click on the Close button in the upper-right corner of the window to exit the Hyper Terminal.
Close all the opening windows before exiting Windows
®
95/98/Me/XP.