89
9
0.00
OFF
The network
is unstable.
The network setting is incorrect.
Check the network setting with the PROFIBUS-DP
network configuration software.
The inverter is affected by the
other nodes.
Check if any network error has occurred in the other
nodes.
No master is present in the network, or the master
is not properly operating.
Check the connection and the operation of the
PROFIBUS-DP master.
Red (ON)
The PROFIBUS communication had been
established (the green LED had been ON), but
the master stopped transmitting data to the option
unit during an inverter stop.
Check the master ladder, etc., and remove the causes
that disconnect the data transmission between the
master and the option unit.
E.OP1
Red (ON)
A communication cable break occurred after the
PROFIBUS communication had been established
(green LED had been ON).
Check the connection and the wiring of the
communication cable.
Communication errors occurred consecutively
after the PROFIBUS communication had been
established (green LED had been ON).
Connect a terminating resistor. If a terminating resistor
has been already connected, check if it is connected
properly.
The PROFIBUS communication had been
established (the green LED had been ON), but
the master stopped transmitting data to the option
unit during an inverter operation.
Check the master ladder, etc., and remove the causes
that disconnect the data transmission between the
master and the option unit.
Operation
panel display
on the inverter
LED on
FR-A8NP
Possible cause
Checkpoint / troubleshooting
Содержание FR-A8NP