28
INVERTER SETTING
• Operation at error removal
NOTE
• The protective function [E.OP1 (fault data: HA1)] is activated at error occurrences on the communication line. The
protective function [E.1 (fault data: HF1)] is activated at error occurrences in the communication circuit inside the
option.
• Fault output indicates the fault (ALM) signal and fault bit output.
• When the fault output setting is active, fault records are stored in the faults history. (A fault record is written to the
faults history at a fault output.)
When the fault output setting is not active, fault record is overwritten to the faults history temporarily but not stored.
After the error is removed, the fault indication is reset, changing the display back to normal, and the last fault is
displayed in the faults history.
• When the
Pr.502
setting is "1 or 2", the deceleration time is the ordinary deceleration time setting (e.g.
Pr.8, Pr.44,
Pr.45
).
• The acceleration time at a restart is the ordinary acceleration time setting (e.g.
Pr.7, Pr.44
).
• When the
Pr.502
setting is "2", the operation/speed command at a restart is the one given before the error occurrence.
• When a communication line error occurs at the
Pr.502
setting of "2", removing the error during deceleration causes
acceleration to restart at that point. (Acceleration is not restarted if the error is that of the option unit itself.)
• When
Pr.502
= "3", in order to continue the operation in the case of a communication line error, provide a safety stop
countermeasure other than via communication. One counter measure is to input a signal to the terminal RES.
Fault description
Pr.502 setting
Operation
Indication
Fault output
Communication line
0
Kept stopped
E.OP1 kept lit
Kept provided
1
2
Restart
Normal indication
Not provided
3
Normal operation
Communication option
itself
0, 3
Kept stopped
E. 1 kept lit
Kept provided
1, 2
Содержание FR-A8NP