50
PPO TYPE SUPPORT SPECIFICATION
ECW
(Extended format)
Terminal RH function
0
High speed operation command
Functions assigned to terminal RH, RM,
RL, JOG, AU and CS are activated.
Terminal RM function
1
Middle-speed operation command
Terminal RL function
2
Low-speed operation command
Terminal JOG function
3
Terminal AU function
4
Current input selection
Terminal CS function
5
Selection of automatic restart after
instantaneous power failure
REF2 enable
6
0: REF2 disabled, 1: REF2 enabled (The REF2 setting is applied to the inverter.)
REF3 enable
7
0: REF3 disabled, 1: REF3 enabled (The REF3 setting is applied to the inverter.)
REF4 enable
8
0: REF4 disabled, 1: REF4 enabled (The REF4 setting is applied to the inverter.)
REF5 enable
9
0: REF5 disabled, 1: REF5 enabled (The REF5 setting is applied to the inverter.)
REF6 enable
10
0: REF6 disabled, 1: REF6 enabled (The REF6 setting is applied to the inverter.)
REF7 enable
11
0: REF7 disabled, 1: REF7 enabled (The REF7 setting is applied to the inverter.)
Command count
12 to 15
Used by the master to recognize the command response.
ESW
(Standard format)
SU signal
0
0: OFF, 1: ON (up to frequency)
OL signal
1
0: OFF, 1: ON (overload alarm)
IPF signal
2
0: OFF, 1: ON (an instantaneous power failure or undervoltage occurs)
Terminal RUN function
3
Inverter running
The function assigned to the terminal
RUN is activated.
—
4 to 7
Not used (0 is set)
Command count
8 to 15
Echo back of the command request.
Name
Bit
Definition