131
Remo
te output
function
(R
EM signal)
495
Remote output
selection
1
0
0
Remote output data
clear at powering off
No remote output
data held at
resetting
{
{
{
1
Remote output data
held at powering off
10
Remote output data
clear at powering off
Remote output
data held at
resetting
11
Remote output data
held at powering off
496
Remote output data 1
1
0
0 to 4095
Output terminal can be switched on and
off.
×
×
×
497
Remote output data 2
1
0
0 to 4095
×
×
×
Maintenance of p
art
s
503
Maintenance timer
1
0
0 (1 to 9998)
Displays the cumulative energization time
of the inverter in 100h increments.
Reading only
Writing the setting of "0" clears the
cumulative energization time.
×
×
×
504
Maintenance timer
alarm output set time
1
9999
0 to 9998
Set the time taken until when the
maintenance timer alarm output signal
(Y95) is output.
{
×
{
9999
No function
—
505
Refer to
Pr. 37
.
—
516 to 519
Refer to
Pr. 29
.
539
Refer to
Pr. 343
.
—
547, 548
Parameter for manufacturer setting. Do not set.
549 to 551
Refer to
Pr. 343
.
Cur
rent aver
age
value
monito
r signa
l
555
Current average
time
0.1s
1s
0.1 to 1.0s
Set the time taken to average the current
during start bit output (1s).
{
{
{
556
Data output mask
time
0.1s
0s
0.0 to 20.0s
Set the time for not obtaining (mask)
transient state data.
{
{
{
557
Current average
value monitor signal
output reference
current
0.01A
Rated
inverter
current
0 to 500A
Set the reference (100%) for outputting the
signal of the current average value.
{
{
{
563, 564
Refer to
Pr. 52
.
569
Refer to
Pr. 80
.
—
571
Refer to
Pr. 13
.
574
Refer to
Pr. 95
.
575 to 577
Refer to
Pr. 127.
611
Refer to
Pr. 57
.
665
Refer to
Pr. 882
.
684
Refer to
Pr. 82
.
800
Refer to
Pr. 81
.
802
Refer to
Pr. 10
.
803
Refer to
Pr. 22
.
To
rque command sour
ce selection
804
Torque command
source selection
1
0
0
Torque command by terminal 1 analog
input
{
{
{
1
Torque command by parameter
Pr.805
or
Pr.806
setting (-400% to 400%)
3
Torque command by using CC-Link (FR-
A7NC)
4
Digital input from the option (FR-A7AX)
5
Torque command by using CC-Link (FR-
A7NC)
6
805
Torque command
value (RAM)
1%
1000%
600 to
1400%
Digital setting of the torque command can
be made by setting
Pr. 805
or
Pr. 806
.
(Setting from communication option, etc.
can be made.)
In this case, set the speed limit value to an
appropriate value to prevent overspeed.
×
{
{
806
Torque command
value
(RAM,EEPROM)
1%
1000%
600 to
1400%
{
{
{
Fu
nc
tio
n
Parameter
Name
Incre
ments
Initial
Value
Range
Description
Para
meter
copy
Param
eter
clear
All
param
eter
clear
Re
la
te
d
p
a
ra
mete
rs
{
: enabled
×
: disabled