110
Outp
ut function
of alarm code
76
Fault code output
selection
1
0
0
Without fault code output
{
{
{
1
With fault code output
2
Fault code output at fault occurrence only
P
revention
of
pa
ra
m
et
e
r
re
w
rite
77
Parameter write
selection
1
0
0
Write is enabled only during a stop
{
{
{
1
Parameter write is disabled.
2
Parameter write is enabled in any
operation mode regardless of operating
status.
Prevention of
rev
ers
e ro
ta
tio
n
of the mo
tor
78
Reverse rotation
prevention selection
1
0
0
Both forward and reverse rotations allowed
{
{
{
1
Reverse rotation disallowed
2
Forward rotation disallowed
Oper
atio
n mode selection
79
Operation mode
selection
1
0
0
External/PU switchover mode
{
{
{
1
Fixed to PU operation mode
2
Fixed to External operation mode
3
External/PU combined operation mode 1
4
External/PU combined operation mode 2
6
Switchover mode
7
External operation mode (PU operation
interlock)
340
Communication
startup mode
selection
1
0
0
As set in
Pr. 79
.
{
{
{
1, 2
Started in the network operation mode.
When the setting is "2", it will resume the
pre-instantaneous power failure operation
mode after an instantaneous power failure
occurs.
10, 12
Started in the network operation mode.
Operation mode can be changed between
PU operation mode and network operation
mode from the operation panel.
When the setting is "12", it will resume the
pre-instantaneous power failure operation
mode after an instantaneous power failure
occurs.
Fu
nc
tio
n
Parameter
Name
Incre
ments
Initial
Value
Range
Description
Para
meter
copy
Param
eter
clear
All
param
eter
clear
Re
la
te
d
p
a
ra
mete
rs
{
: enabled
×
: disabled