107
Automatic acceler
atio
n/dece
ler
ation
61
Reference current
0.01A
9999
0 to 500A
Setting value (rated motor current) is
referenced
{
{
{
9999
Rated inverter current is referenced
62
Reference value at
acceleration
0.1%
9999
0 to 220%
Setting value is a limit
value
Shortest acceleration/
deceleration mode
{
{
{
Setting value is an
optimum value
Optimum
acceleration/
deceleration mode
9999
150% is a limit value
Shortest acceleration/
deceleration mode
100% is an optimum
value
Optimum
acceleration/
deceleration mode
63
Reference value at
deceleration
0.1%
9999
0 to 220%
Setting value is a limit
value
Shortest acceleration/
deceleration mode
{
{
{
Setting value is an
optimum value
Optimum
acceleration/
deceleration mode
9999
150% is a limit value
Shortest acceleration/
deceleration mode
100% is an optimum
value
Optimum
acceleration/
deceleration mode
64
Starting frequency
for elevator mode
0.01Hz
9999
0 to 10Hz
0 to 10Hz are starting frequency
{
{
{
9999
2Hz is starting frequency
292
Automatic
acceleration/
deceleration
1
0
0
Normal mode
{
{
{
3
Optimum acceleration/deceleration mode
5
Elevator mode 1
6
Elevator mode 2
7
Brake sequence mode 1
8
Brake sequence mode 2
11
Shortest acceleration/deceleration mode
293
Acceleration/
deceleration
separate selection
1
0
0
Calculate acceleration/deceleration time of
both acceleration and deceleration for the
shortest and optimum acceleration/
deceleration mode.
{
{
{
1
Calculate only acceleration time for the
shortest and optimum acceleration/
deceleration mode
2
Calculate only deceleration time for the
shortest and optimum acceleration/
deceleration mode
Re
try function a
t alar
m occur
rence
65
Retry selection
1
0
0 to 5
A fault for retry can be selected.
{
{
{
67
Number of retries at
fault occurrence
1
0
0
No retry function
{
{
{
1 to 10
Set the number of retries at fault
occurrence. A fault output is not provided
during retry operation.
101 to 110
Set the number of retries at fault
occurrence. (The setting value -100 is the
number of retries.) A fault output is provided
during retry operation.
68
Retry waiting time
0.1s
1s
0 to 10s
Set the waiting time from when an inverter
fault occurs until a retry is made.
{
{
{
69
Retry count display
erase
1
0
0
Clears the number of restarts succeeded
by retry.
{
{
{
—
66
Refer to
Pr. 22 and Pr. 23
.
67 to 69
Refer to
Pr. 65
.
Fu
nc
tio
n
Parameter
Name
Incre
ments
Initial
Value
Range
Description
Para
meter
copy
Param
eter
clear
All
param
eter
clear
Re
la
te
d
p
a
ra
mete
rs
{
: enabled
×
: disabled