HIGH RESOLUTION ANALOG INPUT
5
(4) Calibration of stall prevention operation level (
Pr. 406
= "4")
When
Pr. 406
= "4" under V/F control and Advanced magnetic flux vector control, terminal 6 acts as stall
prevention operation level and
Pr. 148
and
Pr. 149
are used for calibration parameter.
(5) Calibration of torque bias input (
Pr. 406
= "6")
When
Pr. 406
= "6", terminal 6 acts as torque bias input and
Pr. 846 to Pr. 848, C34 to C37
are used for
calibration parameter.
Current limit level(%)
Initial value
10V
-10V
Input voltage
0V
200%
150%
Current limit level
at 10V input
(
Pr. 149
)
Current limit level at 0V input (
Pr. 148
)
Bias amount
Torque bias
Gain
C36 (Pr. 929)
Input voltage
150%
0
Voltage for max. load
Voltage for balanced load
Pr. 846
Torque bias
Bias
C34 (Pr. 928)
Initial value
<When the motor runs in forward rotation direction>
Pr. 840
= "1" (at driving when the motor is in forward rotation)
Bias amount
Fall-time
torque bias
Gain
Pr. 848
Input voltage
150%
0
Voltage for max. load
Voltage for balanced load
Pr. 846
Fall-time
torque bias
Bias
Pr. 847
Initial value
<When the motor runs in reverse rotation direction>
C35 (Pr. 928)
C37 (Pr. 929)