HIGH RESOLUTION ANALOG INPUT
(2) Filter of terminal 6 input
When giving the speed command or limiting the speed from terminal 6 input, settings of
Pr. 822 Speed
setting filter 1
and
Pr. 832 Speed setting filter 2
are valid.
When giving the torque command or limiting the torque from terminal 6 input, settings of
Pr. 826 Torque
setting filter 1
and
Pr. 836 Torque setting filter 2
are valid.
Refer to
the Inverter Manual
for details of
Pr. 822 Speed setting filter 1, Pr. 832 Speed setting filter 2, Pr. 826
Torque setting filter 1, and Pr. 836 Torque setting filter 2
.
(3) Calibration and adjustment of terminal 6
When "0" is set in
Pr.406
,
terminal 6 is used for speed command and speed limit inputs, and terminal 2
becomes invalid for those inputs.
Pr. 242 Terminal 1 added compensation amount (terminal 2)
becomes valid for terminal 6 and
compensation of terminal 6 input is made by terminal 1 input.
Pr. 849 Analog input offset adjustment
becomes valid for terminal 6 and terminal 6 input is provided with
offset.
Refer to
the Inverter Manual
for details of
Pr. 242 Terminal 1 added compensation amount (terminal 2)
and
Pr. 849
Analog input offset adjustment
.
(4) Torque bias of terminal 6
When "6" is set in
Pr. 406
High resolution analog input selection
, terminal 6 is used for torque bias input.
Pr. 846 Torque bias balance compensation, Pr. 847 Fall-time torque bias terminal 1 bias, Pr. 848 Fall-time
torque bias terminal 1 gain
become valid for terminal 6.