![Mitsubishi Electric FR-A720-55K Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/mitsubishi-electric/fr-a720-55k/fr-a720-55k_instruction-manual_239754030.webp)
25
HIGH RESOLUTION ANALOG INPUT
5
5.3.3 Calibration of terminal 6 (Pr. 148, Pr. 149, Pr. 846 to Pr. 848, C30 to C37)
(1) Terminal 6 calibration parameter
Use the following parameters for calibration of terminal 6 according to the
Pr. 406
setting.
Pr. 406
Setting
Terminal 6
Function
Calibration Parameters
Related
Parameters
Bias setting
Gain setting
0
Speed command/
speed limit
C30 (Pr. 926) Terminal 6 bias frequency (speed)
C31 (Pr. 926) Terminal 6 bias (speed)
C32 (Pr. 927) Terminal 6 gain frequency (speed)
C33 (Pr. 927) Terminal 6 gain (speed)
Pr. 822, Pr. 832
Pr. 242, Pr. 849
2
Regenerative
torque limit
C34 (Pr. 928) Terminal 6 bias command (torque)
C35 (Pr. 928) Terminal 6 bias (torque)
C36 (Pr. 929) Terminal 6 gain command (torque)
C37 (Pr. 929) Terminal 6 gain (torque)
Pr. 826, Pr. 836
3
Torque
command
C34 (Pr. 928) Terminal 6 bias command (torque)
C35 (Pr. 928) Terminal 6 bias (torque)
C36 (Pr. 929) Terminal 6 gain command (torque)
C37 (Pr. 929) Terminal 6 gain (torque)
Pr. 826, Pr. 836
4
Torque limit/
torque command
C34 (Pr. 928) Terminal 6 bias command (torque)
C35 (Pr. 928) Terminal 6 bias (torque)
C36 (Pr. 929) Terminal 6 gain command (torque)
C37 (Pr. 929) Terminal 6 gain (torque)
Pr. 826, Pr. 836
Stall prevention
operation level
Pr. 148 Stall prevention level at 0V input
Pr. 149 Stall prevention level at 10V input
5
Forward rotation
reverse rotation
speed limit
C30 (Pr. 926) Terminal 6 bias frequency (speed)
C31 (Pr. 926) Terminal 6 bias (speed)
C32 (Pr. 927) Terminal 6 gain frequency (speed)
C33 (Pr. 927) Terminal 6 gain (speed)
Pr. 822, Pr. 832
6
Torque bias
C34 (Pr. 928) Terminal 6 bias command (torque)
C35 (Pr. 928) Terminal 6 bias (torque)
Pr. 846 Torque bias balance compensation
Pr. 847 Fall-time torque bias terminal 1 bias
C36 (Pr. 929) Terminal 6 gain command (torque)
C37 (Pr. 929) Terminal 6 gain (torque)
Pr. 846 Torque bias balance compensation
Pr. 848 Fall-time torque bias terminal 1 gain
9999
(initial
value)
⎯
⎯
⎯