![Mitsubishi Electric FR-A720-55K Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/mitsubishi-electric/fr-a720-55k/fr-a720-55k_instruction-manual_239754022.webp)
17
BIPOLAR ANALOG OUTPUT
4
4.2
Terminals
4.3
Bipolar analog outputting parameter
4.3.1 Parameter list
The following parameters are used for outputting bipolar analog.
*1
They can be set only when used with the FR-A7AZ.
*2
The parameter number in parentheses is the one for use with the parameter unit (FR-PU07/FR-PU04).
Terminal Symbol
Terminal Name
Description
DA1
Bipolar analog output
terminal
Connect a DC indicator (±10VDC).
5
Common terminal
Common terminal of the DA1
Parameter
Number
Name
Setting Range
Minimum
Increments
Initial
Value
838
*1
DA1 terminal function selection
1 to 3, 5 to 14, 17, 18, 21,
24, 32 to 34, 36, 46, 50,
52, 53
1
2
839
*1
DA1 output filter
0 to 5s
0.001s
0.05s
857
*1
DA1-0V adjustment
900% to 1100%
1%
1000%
C0 (900)
*2
FM(CA) terminal calibration
⎯
⎯
⎯
5
TST
5
5
5
TH2
6
TST
DA1
5
5
TH1