![Mitsubishi Electric FR-A720-55K Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/mitsubishi-electric/fr-a720-55k/fr-a720-55k_instruction-manual_239754019.webp)
14
3
PARAMETER LIST
Use the following parameters with the FR-A7AZ.
Set these as required.
Parameter
Number
Name
Setting Range
Minimum
Increments
Initial
Value
Refer to
Page
406
*1
High resolution analog input selection
0, 2 to 6, 9999
1
9999
407
*1
Motor temperature detection filter
0 to 100s, 9999
1s
9999
408
*1
Motor thermistor selection
0, 1
1
0
750
*1
Motor temperature detection level
0 to 200°C
1°C
75°C
751
*1
Reference motor temperature
1 to 200°C
1°C
150°C
838
*1
DA1 terminal function selection
1 to 3, 5 to 14, 17, 18,
21, 24, 32 to 34, 36,
46, 50, 52, 53
1
2
839
*1
DA1 output filter
0 to 5s
0.001s
0.05s
846
Torque bias balance compensation
0 to 10V, 9999
0.1V
9999
847
Fall-time torque bias terminal 1 bias
0 to 400%, 9999
1%
9999
848
Fall-time torque bias terminal 1 gain
0 to 400%, 9999
1%
9999
857
*1
DA1-0V adjustment
900 to 1100%
1%
1000%
C0 (900)
*2
FM(CA) terminal calibration
−
−
−
C29 (925)
*1, 2
Motor temperature detection
calibration (analog input)
0 to 200%
0.1%
100%
C30 (926)
*2
Terminal 6 bias frequency (speed)
0 to 400Hz
0.01Hz
0Hz