54
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
Various recordings
■
PRE ALARM RECORDINGS
During alarm recording, recording can be started a few
seconds before the ALARM IN terminal is grounded or
motion is detected.
For details concerning pre-alarm recording set-
tings,
see “Recording mode settings A - D for
normal recording / alarm recording” page 42.
Time
disturbance
Alarm input
Records data on HDD before alarm is input.
Camera input
Recording process
Pre-alarm recording :
1) The PRE-ALARM indicator flashes during pre-alarm
recording and lights during standby.
2) Starts recording video before the ALARM IN terminal is
ground or motion is detected.
3) Can only be executed when pre-alarm recording has
been set in the <RECORD SETTING> screen or
<REC MODE A> - <REC MODE D> screen. The recording
channels after input of an alarm signals is executed only of
camera set in the <RECORD SETTING> screen and
<REC MODE A> - <REC MODE D> screen.
Pre-alarm recording and normal recording can-
not be executed simultaneously.
The pre-alarm recording time differs depending
on the recorded contents. The recording time may
also differ depending on the video contents or the
timing of the alarm signal input.
Although playback is available while the PRE-
ALARM indicator is on, normal recording cannot be
made.
■
EMERGENCY RECORDINGS
If the EMERGENCY terminal is grounded when the MAIN
switch on the rear of the unit, and the POWER button on
the front of the unit are both ON and during timer record-
ing, EMERGENCY RECORDING will start automatically
overriding all other settings.
Emergency recording cannot be made when the
MAIN switch is OFF, the POWER button is OFF
and during timer recording standby.
For details concerning emergency recording set-
tings,
see page 47.
Emergency recording :
1) Records only for the time specified in recording interval
“30P” and recording picture quality “SUPER”.
2) Cameras used
• Recording is performed using all cameras other than those
set to “- - - - - -” in “PPS” and “- - - - - -” in “A-PPS”.
• During timer recording, recording is performed using all
cameras other than those set to “- - - - - -” in the recording
mode of the set time frame.
3) During recording
• The EMERGENCY indicator flashes and then lights when
recording is completed. To turn off the indicator, display
the <ALARM LIST SEARCH> screen and press the WARN-
ING RESET button for more than 5 seconds.
• The camera number buttons that are used for alarm re-
cording and the camera number display on the screen
flashes.
• The operation mode “ALARM REC” (in red) is displayed
on the screen.
4) Recording is stored and displayed in the alarm list in
red.
■
SERIES RECORDINGS
When connecting 2 units, recording with the second unit
can be set to start automatically when the HDD space of
the first unit becomes FULL or when there is a failure dur-
ing HDD recording.
Not available during timer recording.
♦
Setting example for series recording 1
Setting for operating the 2 units as shown below.
• When the remaining capacity of the first unit becomes
less than 20% during HDD recording
}
}
}
}
}
Automatically start recording to the HDD of the
second unit
• When the remaining capacity of the second unit becomes
less than 20% during HDD recording
}
}
}
}
}
Automatically start recording to the HDD of the
first unit by overwriting existing data (it is also
possible to set to that data of the first unit is
not overwritten).
CLOCK ADJ
REC
EMERGENCY
RESERVED
MODE OUT 1
MODE OUT 2
MODE OUT 3
MODE OUT 4
CALL OUT
CALL OUT GND
MAX 30mA
DC 5V OUT
GND
CLOCK ADJ
REC
EMERGENCY
RESERVED
MODE OUT 1
MODE OUT 2
MODE OUT 3
MODE OUT 4
CALL OUT
CALL OUT GND
MAX 30mA
DC 5V OUT
GND
First Unit
Second Unit
This connection is not required
when not overwriting data on the first unit.
The following settings are performed for both units.
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
Select “HDD REPEAT REC” in the
<HDD SETTINGS> screen. Display the “STANDBY” and
confirm.
Содержание DX-TL900U