46
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
<INITIAL SET UP/INFORMATION> (continued)
♦
REMAIN HDD
A warning indicating that the remaining HDD capacity has
become low during recording is outputted. The remaining
capacity for this warning is set here.
<REAR TERMINAL SETTINGS>
MODE OUT 1 OFF
MODE OUT 2 OFF
MODE OUT 3 OFF
MODE OUT 4 OFF
KEY SOUND ON
BUZZER OFF
>>REMAIN HDD HDD-10
%
CALL OUT SETTINGS
EMERGENCY REC DURATION 10M
A warning is outputted using the following meth-
ods when the remaining capacity becomes low dur-
ing recording.
• The HDD usage display flashes when “3” is set to
“DISPLAY MODE” in the <TIME DATE/DISPLAY
SETTINGS> screen.
• A buzzer will sound when “REMAIN” is set to
“BUZZER” in the <REAR TERMINAL SETTINGS>
screen.
Setting of DEVICE ( default : “HDD” )
“HDD” : Displays a warning of low HDD capacity.
“OFF” : Does not display warning of low HDD ca-
pacity.
Setting of “REMAIN HDD” ( default : “10%” )
“2%”, “4%”, “6%”, “8%”, “10%”, “15%”,“20%”, “30%”,
“40%”, “50%”
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
Select “REMAIN HDD” in the <REAR
TERMINAL SETTINGS> screen and turn the SHUTTLE ring
clockwise twice.
• The setting display reverses in color when the SHUTTLE
ring is turned the first time. When the ring is turned for the
second time, the background turns red and flashes.
2. Turn the JOG dial to display the desired device and turn the
SHUTTLE ring clockwise.
• The setting is confirmed and flashing stops.
3. Turn the JOG dial clockwise to move the reversed display
to the REMAIN HDD value and turn the SHUTTLE ring
clockwise.
• The background of the REMAIN HDD value turns red and
flashes.
4. Turn the JOG dial to display the desired capacity and turn
the SHUTTLE ring clockwise.
• The setting is confirmed and flashing stops.
5. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
♦
CALL OUT SETTINGS
The CALL OUT setting is a setting used to notify via the
rear terminals when a warning signals is activated. The
warning signal can be activated by a malfunction or a HDD
setting being monitored. To reduce miswiring, the CALL
OUT terminal output is a photo coupler output.
see page
16 “CALL OUT output terminal” ).
• HDD REMAIN
When reaching the set remaining HDD capacity, a signal is
outputted from the CALL OUT terminal and “REC/REM” is
displayed.
<CALL OUT SETTINGS>
>>HDD REMAIN OFF
HDD FULL OFF
Setting ( default : “OFF” )
“2%”, “4%”, “6%”, “8%”, “10%”, “15%”,“20%”, “30%”,
“40%”, “50%”, “OFF”
1. Press the SET UP button
}
<SETTINGS>
}
<INITIAL SET
UP/INFORMATION>
}
<REAR TERMINAL SETTINGS>
}
Select “HDD REMAIN” in the <CALL OUT SETTINGS>
screen. Display the desired setting and confirm.
2. Turn the SHUTTLE ring counterclockwise or press the SET
UP button.
By pressing the WARNING RESET button, the
HDD capacity warning from the CALL OUT terminal
can be cancelled.
INFORMATION
For the relationship of the warning display and CALL
OUT signal output,
see page 72. Although the
warning will be displayed regardless if the output
item for the CALL OUT signal is set to “Fixed”, the
condition to output CALL OUT signals can be added
when the output is set to “Selectable”. For example,
the buzzer can be set to sound when reaching a
value set in “HDD REMAIN” of the <CALL OUT SET-
TINGS> screen if “BUZZER” in the <REAR TERMI-
NAL SETTINGS> screen is set to “WARNING”.
• HDD FULL
When the recordable HDD space becomes FULL, a sig-
nal is outputted from the CALL OUT terminal and a “REC/
FULL” warning is displayed.
<CALL OUT SETTINGS>
HDD REMAIN OFF
>>HDD FULL OFF
Setting of device ( default : “OFF” )
“ON” : Signal is outputted when the recording ca-
pacity becomes FULL.
“OFF” : No signal is outputted when the recording
capacity becomes FULL.