17 Troubleshooting
17-182 Occurrence of errors of Tracking and Vision Sensor
Error
number
Error descript
ion
Causes and actions
L8610
Abnormal
communications
[Causes]
Communication with the vision sensor was cut off before or during
command execution.
[Actions]
Check the communication cable between the robot and vision sensor.
L8620
Abnormal vision
sensor number
specification
[Causes]
The specified vision sensor number is not defined with an NVOpen
command.
[Actions]
Check that the specified vision sensor number is correct. Also, check
that that number is defined with an NVOpen command.
L8621
Abnormal vision
program name
[Causes]
The specified vision
program name is more than 15 characters.
[Actions]
Specify a vision program name with no more than 15 characters.
L8622
Vision program not
present.
[Causes]
The specified program does not exist in the specified vision sensor.
[Actions]
Check whether the specified vision program exists in the specified vision
sensor. Also check that the vision program name specified is correct.
L8623
SKIP number is
already used.
[Causes]
SKIP number is already used.
[Actions]
Confirm the SKIP number.
L8630
Incorrec
t value in
recognition count cell
[Causes]
The recognition count value was not in the cell specified as the
recognition count cell.
[Actions]
Check that the correct cell is specified.
L8631
Specified cell value
out of range
[Causes]
Corresponding to either the following.
・
The values specified for the start cell and end cell are reversed.
・
The range specified by Start Cell and End Cell exceeds line 30 and row
10.
・
The number of data included in the cell which specifies it by Start Cell
and End Cell ex
ceeds 90.
[Actions]
・
Check that the correct cell is specified.
・
Check the number of data acquired from the cell which specifies it by
Start Cell and End Cell.
L8632
Vision sensor
response timeout
[Causes]
There is no response from vision sensor within the specified time or
within a specific time.
[Actions]
Check that the specified time is correct. Or check that the vision sensor
settings are correct.
L8636
Vision Tag name is
abnormal
[Causes]
The active specified symbolic tag does not exist in the vision program.
[Actions]
Please confirm the name of symbolic tag of Easy Builder is
corresponding to the tag name specified by the robot program, and
correct the tag name.