![Mitsubishi Electric CR800 Series Скачать руководство пользователя страница 167](http://html.mh-extra.com/html/mitsubishi-electric/cr800-series/cr800-series_instruction-manual_238852167.webp)
15 Maintenance of robot program
MELFA-BASIC V or MELFA-BASIC VI instruction 15-155
[Terminology]
< Condition number
[Integer]
>
Specify the condition number corresponding to the tracking.
Setting range: 1 to 8
<Position data
[Position]
>
Specify the base position of the tracking.
<Position variable
[Position]
>
Return the base coordinates of the specified tracking.
[Reference program]
P_TrkBase(1) = PTBASE
’Specify the tracking base.
・・・・・
*LTRST
TrkMv On, PGTUP, 1, *S91STOP
’Start the interrupt processing->Trk On->Move to the tracking upper
position
[Explanation]
(1)
Specify the workpiece coordinate system origin used in tracking command “TrkMv”.
(2)
You can confirm the workpiece coordina
te system origin by referencing “P_TrkBase”.
(3) You can omit the step to specify <Condition number>.When it is omitted, condition number will be treated as
"1."
(4)
Number which you can enter to specify <Condition number> is an integer in the range of "1" to "8."
Entering
anything else causes L3110 (Argument value range over) error to occur.
Содержание CR800 Series