4-76 Handling the controller
4Basic operations
Fig.4-5 : Names of controller parts (inside of CR760)
Use the network equipments (personal computer, USB hub, LAN hub, etc) confirmed by
manufacturer. The thing unsuitable for the FA environment (related with conformity,
temperature or noise) exists in the equipments connected to USB. When using network
equipment, measures against the noise, such as measures against EMI and
the addition of the ferrite core, may be necessary. Please fully confirm the operation
by customer. Guarantee and maintenance of the equipment on the market (usual office
automation equipment) cannot be performed.
POWER
CR760
!
⑤SLOT1
⑥SLOT2
⑦SLOT3
R700CPUユニット
OPT1
(予約済)
⑨OPT2
⑩MEMORY CASSETTE
⑫CNENC
⑧RIO
⑪LAN1
① Earth leakage breaker......................................................................... Connect the primary power source.
② Grounding plate ..................................................................................... The grounding terminal for grounding the cable. (Strip off the
sheath of the cable and ground the controller case using this
plate.)
③ EMG1 connector................................................................................... External emergency stop input, door switch input, enabling
device switch, and magnet contactor control connector out
-
put for addition axes
④ EMG2 connector................................................................................... Emergency stop output, mode output, robot error output, and
special stop input (SKIP).
⑤⑥⑦ Option slot (SLOT1, SLOT2, SLOT3)................................ Install the interface optional.
⑧ Extension parallel input/output unit connection connector (RIO)
Connect the extension parallel input/output unit.
⑨ Addition axis connection connector (OPT2) ............................ Connect the cable for addition axis control.
⑩ Expansion memory cassette (MEMORY CASSETTE) .......... Install the memory cassette optional.
⑪ Ethernet interface (LAN1)................................................................ Connect the Ethernet cable.
⑫ Tracking interface (CNENC)............................................................ Connect the encoder cable, if it uses the tracking function.
⑬ Transformer box (CE marking specification only) .................. Connect a power cable and a grounding cable.
View A: inside of CR760 controller
②
③
④
R700CPU unit
(Reserved)
①
<Non-CE marking
specification>
<CE marking speci
-
fication>
A
⑬
CAUTION
Содержание CR750-D Series