2-56 Installation
Fig.2-40 : Example of safety measures (Wiring example 5)
OP
E-stop
入力
検知
回路
10μF
入力
検知
回路
1
13
3
15
5
17
EMG1
内部リレー
TB
E-stop
24G
2
14
4
16
6
18
24G
内部リレー
X0
COM0
X1
COM1
No connection
No connection
安全入力1
安全入力2
24V DC
24G
安全リレー
お客様電源(DC 24V)
+24V
24G
お客様装置
24V DC
外部非常停止スイッチ
5
17
24V DC
24V DC
外部非常停止スイッチ
6
18
24V DC
安全リレー
非常停止出力
非常停止出力
No connection
No connection
例)QS90SR2SP
( 三菱電機株式会社)
EMG1
EMG2
EMG2
10μF
[Caution]
1)This product has category 3 functionality and therefore the robot’s whole unit cannot be set to category 4.
2)The controller’s internal circuit has polarity. Please adhere to the polarity as detailed in the wiring examples, particularly
for emergency stop button output when using user equipment. Connect the positive side of the user equipment (24V DC)
to the two terminals 13/14 of EMG1, then connect the emergency stop button (or contact points) in the user equipment
to the 3-15 and 4-16 terminals of EMG1, and ultimately connect the negative side (24G).
3)When installing a safety relay to use it as an input point of the controller's emergency stop button command, use a safety
relay that is activated by an input from one of the two systems (i.e. QS90SR2SP (Manufacture: Mitsubishi Electric
Corporation)).
4)The emergency stop input detection relay (internal relay) uses the controller’s internal safety relay control. If the
emergency stop input detection relay is switched OFF, emergency stop is detected and the safety relay is also switched
OFF.
5)When connecting emergency stop button output to an external safety relay, please take note of the polarity and make
sure that the electrical current flows in the same direction as indicated by the dotted arrows in the two places in the
diagram. If the polarity is setup incorrectly, this function will not operate correctly. Please connect the two terminals 5/6
of EMG2 to 24V.
<Wiring example 5>: Connect the controller to the safety relay
Use the controller’s emergency stop button command as an input to the safety relay.
Controller
External emergency stop switch
Internal relay
Safety relay
Emergency stop
output
External emergency stop
switch
Internal relay
Emergency stop
output
Customer equipment
Safety relay
ex) QS90SR2SP (Mitsubi
-
shi Electric Corporation)
Safety
input 1
Safety
input 2
Customer Power Supply (DC 24V)
Input
detection
circuit
Input
detection
circuit