For users operating robots that have not been mounted with an operation panel:
Operation of robot programs such as start-up and shutdown are carried out using external signals
(exclusive input/output signals). This instruction manual is based on robots that are mounted with an
operation panel at the front of the controller, and these operations are explained using key opera-
tions on that panel. Using the parameter settings, please assign exclusive input/output signals that
correspond with each key operation to general purpose input/output signals, and operate the robot
using signal operations.
The following table details exclusive input/output signals that correspond with the key operations of
the operation panel explained in this manual. Please use this as a reference to assign signals and
operate the robot.
For further details regarding parameters please see the separate instruction manual "Detailed expla-
nations of functions and operations".
Table: Conversion table of the buttons and dedicated I/O signals
Operation panel
button, lamp
Parameter
name
Class
Function
Default
setting
START button
START button lamp
START
Input
Starts a program.
3,0
Output
Indicates that a program is being executed.
STOP button
STOP
button lamp
STOP
Input
Stops a program.
0,-1
Output
Indicates that the program is paused.
RESET
button
RESET
button lamp
ERRRESET
Input
Releases the error state.
2,2
Output
Indicates that an error has occurred.
SLOTINIT
Input
Cancels the paused status of the program and brings the exe-
cuting line to the top. Executing a program reset makes it possi-
ble to select a program.
-1,-1
Output
Outputs that in the program selection enabled state.
CHNG DISP
button
UP/DOWN
button
PRGSEL
Input
Selects the value inputted into the signal assigned to the numer-
ical input as a program number.
-1,
Output
-
PRGOUT
Input
Outputs the program number selected to the signal assigned to
the numerical output.
-1,-1
Output
Indicates outputting the program number to the numerical out-
put.
OVRDSEL
Input
Sets the value inputted into the signal assigned to the numerical
input as a override.
-1,
Output
-
OVRDOUT
Input
Outputs the override value to the signal assigned to the numeri-
cal output.
-1,-1
Output
Indicates outputting the override value to the numerical output.
LINEOUT
Input
Outputs the current line number to the signal assigned to the
numerical output.
-1,-1
Output
Indicates outputting the current line number to the numerical
output.
ERROUT
Input
Outputs the error number to the signal assigned to the numerical
output.
-1,-1
Output
Indicates outputting the error number to the numerical output.
IODATA
Input
Reads the program number and the override value as a binary
value.
-1,-1,
-1,-1
Output
Outputs the program number, line number and override value as
a binary value.
END
button
END
button lamp
CYCLE
Input
Starts the cycle stop.
-1,-1
Output
Outputs that the cycle stop is operating.
SVO.ON
button
SVO.ON
button lamp
SRVON
Input
Turns ON the servo power supply.
4,1
Output
Indicates the servo power supply is ON.
SVO.OFF
button
SVO.OFF
button lamp
SRVOFF
Input
Turns OFF the servo power supply.
1,-1
Output
This output indicates a status where the servo power supply
cannot be turned ON. (Echo back)
Содержание CR750-D Series
Страница 2: ......
Страница 124: ...5 112 Maintenance parts 5Maintenance and Inspection ...
Страница 125: ......