![Mitsubishi Electric CANopen ME3CAN1-L Скачать руководство пользователя страница 70](http://html.mh-extra.com/html/mitsubishi-electric/canopen-me3can1-l/canopen-me3can1-l_user-manual_238822070.webp)
Functions
Communication Profile Area
4 – 4
MITSUBISHI ELECTRIC
4.6 Communication
Profile
Area
The table below provides a brief description and reference information for the ME3CAN1-L
CANopen
Object Dictionary.
Index
(hex)
Sub-index
(hex)
Object
Description
Data type
Initial
value
���
R/W
���
Stored to
Flash ROM
���
1000
00
Device Type
Describes the device profile or the
application profile.
Can be changed by setting the
mode value in Un\G21.
U32
405
R
—
1001
00
Error Register
U8
0
H
R
—
1002
00
Reserved
—
—
—
—
—
1003
00
Pre-defined error field
U8
0
H
R/W
—
01–0F
U32
0
H
R
1004
00
Reserved
—
—
—
—
—
1005
00
COB-ID of SYNC
message
U32
H80
R/W
✔
1006
00
Communication Cycle
Period
U32
0
H
R/W
✔
1007
00
Reserved
—
—
—
—
—
1008
00
Device Name
9 Byte ASCII String
Visible
String
ME3CAN1-L
R
—
1009
00
Hardware Version
4 Byte ASCII String
1.00
R
—
100A
00
Software Version
4 Byte ASCII String
1.00
R
—
100B
00
Reserved
—
—
—
—
—
100C
00
Guard time
U16
0
H
R/W
✔
100D
00
Life time factor
U8
0
H
R/W
✔
100E–100F
00
Reserved
—
—
—
—
—
1010
00
Store parameters
Highest sub-index
U8
01
H
R
—
01
Save all parameters
Refer to section 4.6.10
U32
1
H
R/W
1011
00
Restore default
parameters
Highest sub-index
U8
01
H
R
—
01
Restore all parameters
Refer to section 4.6.11
U32
1
H
R/W
1012
00
COB-ID Time
U32
8000
H
0100
R/W
✔
1013
00
Reserved
—
—
—
—
—
1014
00
COB-ID EMCY
U32
80
H
+
Node ID
R
—
1015
00
Inhibit Time EMCY
U16
0
H
R/W
✔
1016
00
Consumer heartbeat
time
Highest sub-index
U8
7F
H
R
—
01–7F
U32
0
H
R/W
✔
1017
00
Producer heartbeat
time
U16
0
R/W
✔
1018
00
Identity Object
Highest sub-index
U8
03
H
R
—
01
Vendor-ID
U32
71
H
02
Product Code
U32
ED63
H
03
Revision Number
U32
10000
H
1019–101F
00
Reserved
—
—
—
—
—
1020
00
Verify Configuration
Highest sub-index
U8
02
H
R
—
01
U32
0
H
R/W
✔
02
U32
0
H
R/W
✔
1021–1027
00
Reserved
—
—
—
—
—
1028
00
Emergency consumer
object
Highest sub-index
U8
7F
H
R
—
01–7F
U32
80
H
+
Node ID
R/W
✔
1029
00
Error behavior
Highest sub-index
U8
01
H
R
—
01
U8
0
H
R/W
✔
102A
00
NMT inhibit time
U16
0
H
R
—
Tab. 4-6:
Communication profile area of the ME3CAN1-L
Содержание CANopen ME3CAN1-L
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ...IV ...
Страница 18: ...Abbreviations and Generic Terms Overview MELSEC L Series CANopen Module ME3CAN1 L 1 4 ...
Страница 22: ...System Configuration System Equipment 2 4 MITSUBISHI ELECTRIC ...
Страница 66: ...Detailed Description of the Module Buffer Memory Details Layer 2 Message Mode 3 44 MITSUBISHI ELECTRIC ...
Страница 144: ...Programming CANopen PDO Communication using Function Blocks 7 6 MITSUBISHI ELECTRIC Fig 7 6 Example Program 2 ...
Страница 146: ...Programming CANopen PDO Communication using Function Blocks 7 8 MITSUBISHI ELECTRIC Fig 7 8 Example Program 4 ...
Страница 148: ...Programming CANopen PDO Communication using Function Blocks 7 10 MITSUBISHI ELECTRIC Fig 7 10 Example Program 6 ...
Страница 150: ...Programming CANopen PDO Communication using Function Blocks 7 12 MITSUBISHI ELECTRIC Fig 7 12 Example Program 8 ...
Страница 152: ...Programming CANopen PDO Communication using Function Blocks 7 14 MITSUBISHI ELECTRIC Fig 7 14 Example Program 10 ...
Страница 154: ...Programming CANopen PDO Communication using Function Blocks 7 16 MITSUBISHI ELECTRIC Fig 7 16 Example Program 12 ...
Страница 156: ...Programming CANopen PDO Communication using Function Blocks 7 18 MITSUBISHI ELECTRIC Fig 7 18 Example Program 14 ...
Страница 158: ...Programming CANopen PDO Communication using Function Blocks 7 20 MITSUBISHI ELECTRIC Fig 7 20 Example Program 16 ...
Страница 160: ...Programming Layer 2 Communication 7 22 MITSUBISHI ELECTRIC Local Label Setting Fig 7 22 Local Label for this example 1 ...
Страница 161: ...Layer 2 Communication Programming MELSEC L Series CANopen Module ME3CAN1 L 7 23 Fig 7 23 Local Label for this example 2 ...
Страница 162: ...Programming Layer 2 Communication 7 24 MITSUBISHI ELECTRIC Program Fig 7 24 Example Program 1 ...
Страница 163: ...Layer 2 Communication Programming MELSEC L Series CANopen Module ME3CAN1 L 7 25 Fig 7 25 Example Program 2 ...
Страница 164: ...Programming Layer 2 Communication 7 26 MITSUBISHI ELECTRIC Fig 7 26 Example Program 3 ...
Страница 165: ...Layer 2 Communication Programming MELSEC L Series CANopen Module ME3CAN1 L 7 27 Fig 7 27 Example Program 4 ...
Страница 166: ...Programming Layer 2 Communication 7 28 MITSUBISHI ELECTRIC Fig 7 28 Example Program 5 ...
Страница 167: ...Layer 2 Communication Programming MELSEC L Series CANopen Module ME3CAN1 L 7 29 Fig 7 29 Example Program 6 ...
Страница 172: ...Programming Layer 2 Communication 7 34 MITSUBISHI ELECTRIC Fig 7 39 Example Program 2 Set message parameter to module ...
Страница 178: ...Layer 2 Communication Programming MELSEC L Series CANopen Module ME3CAN1 L 7 40 ...
Страница 184: ...Troubleshooting Error Code and Error Message Summary 8 6 MITSUBISHI ELECTRIC ...
Страница 187: ......