![Mitsubishi Electric CANopen ME3CAN1-L Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/mitsubishi-electric/canopen-me3can1-l/canopen-me3can1-l_user-manual_238822051.webp)
Buffer Memory Details: CANopen
Mode
Detailed Description of the Module
MELSEC-L Series – CANopen
Module ME3CAN1-L
3 – 29
Direct transmit buffer memory access to the CiA
-405 Object
Use a TO or MOV instruction to write data to the following locations.
The default TPDO mapping is assigned to unsigned 16 bit objects. To change this setting, please use
the SDO command in the CIF (command interface, refer to sections 4.6.5 and 5.1) or CANopen
net-
work configuration software.
●
Signed and unsigned 8 bit object
NOTE
Data written to the buffer memory will only be copied into the Object Dictionary (OD) when they
are mapped into a PDO.
Example: Un\G13000 is assigned to the OD Indexes/Sub-indexes A240
H
/01
H
, A200
H
/01
H
, A1C0
H
/
01
H
, A100
H
/01
H
, A0C0
H
/01
H
, A040
H
/01
H
, 02
H
and A000
H
/01
H
, 02
H
. If none of these indexes are
mapped into a TPDO the data will not copy from the buffer memory into one of the assigned OD
Indexes/Sub-indexes.
Index (Hexadecimal)
Sub-index
(Hex.)
Buffer memory address
(Decimal)
Unsigned 8 bit object
Signed 8 bit object
A040
A000
01
13000
lower 8 bit
02
higher 8 bit
03
13001
lower 8 bit
04
higher 8 bit
:
:
FD
13126
lower 8 bit
FE
higher 8 bit
A041
A001
01
13127
lower 8 bit
02
higher 8 bit
:
:
FD
13253
lower 8 bit
FE
higher 8 bit
A042
A002
01
13254
lower 8 bit
02
higher 8 bit
:
:
FD
13380
lower 8 bit
FE
higher 8 bit
A043
A003
01
13381
lower 8 bit
02
higher 8 bit
:
:
FD
13507
lower 8 bit
FE
higher 8 bit
A044
A004
01
13508
lower 8 bit
02
higher 8 bit
:
:
FD
13634
lower 8 bit
FE
higher 8 bit
A045
A005
01
13635
lower 8 bit
02
higher 8 bit
:
:
FD
13761
lower 8 bit
FE
higher 8 bit
Tab. 3-25:
Direct transmit buffer memory access for unsigned and signed 8 bit objects
Содержание CANopen ME3CAN1-L
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ...IV ...
Страница 18: ...Abbreviations and Generic Terms Overview MELSEC L Series CANopen Module ME3CAN1 L 1 4 ...
Страница 22: ...System Configuration System Equipment 2 4 MITSUBISHI ELECTRIC ...
Страница 66: ...Detailed Description of the Module Buffer Memory Details Layer 2 Message Mode 3 44 MITSUBISHI ELECTRIC ...
Страница 144: ...Programming CANopen PDO Communication using Function Blocks 7 6 MITSUBISHI ELECTRIC Fig 7 6 Example Program 2 ...
Страница 146: ...Programming CANopen PDO Communication using Function Blocks 7 8 MITSUBISHI ELECTRIC Fig 7 8 Example Program 4 ...
Страница 148: ...Programming CANopen PDO Communication using Function Blocks 7 10 MITSUBISHI ELECTRIC Fig 7 10 Example Program 6 ...
Страница 150: ...Programming CANopen PDO Communication using Function Blocks 7 12 MITSUBISHI ELECTRIC Fig 7 12 Example Program 8 ...
Страница 152: ...Programming CANopen PDO Communication using Function Blocks 7 14 MITSUBISHI ELECTRIC Fig 7 14 Example Program 10 ...
Страница 154: ...Programming CANopen PDO Communication using Function Blocks 7 16 MITSUBISHI ELECTRIC Fig 7 16 Example Program 12 ...
Страница 156: ...Programming CANopen PDO Communication using Function Blocks 7 18 MITSUBISHI ELECTRIC Fig 7 18 Example Program 14 ...
Страница 158: ...Programming CANopen PDO Communication using Function Blocks 7 20 MITSUBISHI ELECTRIC Fig 7 20 Example Program 16 ...
Страница 160: ...Programming Layer 2 Communication 7 22 MITSUBISHI ELECTRIC Local Label Setting Fig 7 22 Local Label for this example 1 ...
Страница 161: ...Layer 2 Communication Programming MELSEC L Series CANopen Module ME3CAN1 L 7 23 Fig 7 23 Local Label for this example 2 ...
Страница 162: ...Programming Layer 2 Communication 7 24 MITSUBISHI ELECTRIC Program Fig 7 24 Example Program 1 ...
Страница 163: ...Layer 2 Communication Programming MELSEC L Series CANopen Module ME3CAN1 L 7 25 Fig 7 25 Example Program 2 ...
Страница 164: ...Programming Layer 2 Communication 7 26 MITSUBISHI ELECTRIC Fig 7 26 Example Program 3 ...
Страница 165: ...Layer 2 Communication Programming MELSEC L Series CANopen Module ME3CAN1 L 7 27 Fig 7 27 Example Program 4 ...
Страница 166: ...Programming Layer 2 Communication 7 28 MITSUBISHI ELECTRIC Fig 7 28 Example Program 5 ...
Страница 167: ...Layer 2 Communication Programming MELSEC L Series CANopen Module ME3CAN1 L 7 29 Fig 7 29 Example Program 6 ...
Страница 172: ...Programming Layer 2 Communication 7 34 MITSUBISHI ELECTRIC Fig 7 39 Example Program 2 Set message parameter to module ...
Страница 178: ...Layer 2 Communication Programming MELSEC L Series CANopen Module ME3CAN1 L 7 40 ...
Страница 184: ...Troubleshooting Error Code and Error Message Summary 8 6 MITSUBISHI ELECTRIC ...
Страница 187: ......