[2] Function Settings
The settings for the following remote controller functions can be changed using the remote controller function
selection mode. Change the settings as necessary.
Function setting flowchart
[1] Stop the unit and go into the remote controller function selection mode. → [2] Select from item 1. → [3] Select from
item 2. → [4] Make the setting. → [5] Return to the Normal Operation screen.
Item 3 (Setting content)
Item 2
Item 1
1. Display language
setting
(“CHANGE
LANGUAGE”)
• Use to select the display language from available languages.
Display language selection
2. Function lock
settings
(“FUNCTION
SELECTION”)
(1) Function lock (“LOCKING FUNCTION”)
• Use to lock functions.
(2) Operation mode skip setting (“SELECT MODE”).
• Use to show or hide specific modes.
(3) Temperature range limit setting (“LIMIT TEMP FUNCTION”)
• Use to restrict the temperature range.
3. Basic function
settings
(“MODE SELEC-
TION”)
(1) Remote controller main/sub setting (“CONTROLLER MAIN/
SUB”)
• Use to designate the remote controller as Main or Sub.
*When two remote controllers are connected to one group, one
controller must be set to sub.
• Use to enable or disable the clock.
(2) Use of clock setting (“CLOCK”)
(3) Timer function setting (“WEEKLY TIMER”)
• Use to show or hide, or enter the emergency contact number.
(4) Contact number setting (“CALL.”)
(5) Temp offset setting (“TEMP OFF SET FUNCTION”)
• Use to show or hide the offset value.
4. Display options
(“DISP MODE
SETTING”)
(1) Temperature unit °C/°F setting (“TEMP MODE °C/°F”)
• Use to show or hide the temperature unit (°C or °F).
(2) Water temperature display setting (“WATER TEMP DISP
SELECT”)
• Use to show or hide the water temperature.
PAR-W21MAA
ON/OFF
TEMP.
MENU
BACK
DAY
CHECK
TEST
MONITOR/SET
CLOCK
CLEAR
ON/OFF
INITIAL SETTING
CIR.WATER
Normal Operation screen (Screen that appears when
the unit is not running)
(Press and hold the
and
buttons for two seconds.)
* No settings can be changed during a test run and self-
diagnosis.
Display language
(“CHANGE LANGUAGE”)
Function lock
(“FUNCTION
SELECTION”)
Basic functions
(“MODE
SELECTION”)
Display options
(“DISP MODE
SETTING”)
Item 1
Press the
button.
Press the
button.
Press the
button.
Press the
button.
Press the
button.
Press the
button.
Press the
button.
Press the
button.
Item 2
Remote Controller Function
Selection Mode
(Press and hold the
and
buttons
for two seconds.)
* The changes made to the settings will
be saved on the remote controller.
Press the
button.
Press the
button.
Press the
button.
Function lock setting (“LOCKING FUNCTION”)
Press the
button.
Operation mode skip setting (“SELECT MODE”)
Temperature range limit setting (“LIMIT TEMP FUNCTION”)
Remote controller main/sub setting (“CONTROLLER MAIN/SUB”)
Press the
button.
Use of clock setting (“CLOCK”)
Timer function setting (“WEEKLY TIMER”)
Contact number setting (“CALL.”)
Temp offset setting (“TEMP OFF SET FUNCTION”)
Temperature unit °C/°F setting (“TEMP MODE °C/°F”)
Press the
button.
Water temperature display setting (“WATER TEMP DISP SELECT”)
See [4]-1
See [4]-2. (1)
See [4]-2. (2)
See [4]-2. (3)
See [4]-3. (1)
See [4]-3. (2)
See [4]-3. (3)
See [4]-3. (4)
See [4]-3. (5)
See [4]-4. (1)
See [4]-4. (2)
Item 3
Dot display
The texts will appear in the
selected language. In this
manual, the texts are in English.
• Use to select a timer type.
E
D
E
D
G
G
G
G
E
E
E
E
G
D
D
D
G
G
F
G
C
D
B
I
A
H
E
Содержание CAHV-P500YA-HPB
Страница 1: ...Service Handbook Service Handbook CAHV P500YA HPB Model 2011 HOT WATER HEAT PUMP ...
Страница 7: ...CONTENTS HWE10060 GB ...
Страница 9: ... 2 HWE10060 GB ...
Страница 19: ... 12 HWE10060 GB ...
Страница 37: ... 30 HWE10060 GB ...
Страница 46: ... 39 HWE10060 GB IV Remote Controller 1 Using the Remote Controller 41 2 Function Settings 46 ...
Страница 47: ... 40 HWE10060 GB ...
Страница 55: ... IV Remote Controller 48 HWE10060 GB ...
Страница 56: ... 49 HWE10060 GB V Electrical Wiring Diagram 1 Electrical Wiring Diagram 51 ...
Страница 57: ... 50 HWE10060 GB ...
Страница 61: ... V Electrical Wiring Diagram 54 HWE10060 GB ...
Страница 62: ... 55 HWE10060 GB VI Refrigerant Circuit 1 Refrigerant Circuit Diagram 57 2 Principal Parts and Functions 58 ...
Страница 63: ... 56 HWE10060 GB ...
Страница 67: ... VI Refrigerant Circuit 60 HWE10060 GB ...
Страница 69: ... 62 HWE10060 GB ...
Страница 101: ... VII Control 94 HWE10060 GB ...
Страница 103: ... 96 HWE10060 GB ...
Страница 109: ... VIII Test Run Mode 102 HWE10060 GB ...
Страница 111: ... 104 HWE10060 GB ...
Страница 155: ... IX Troubleshooting 148 HWE10060 GB ...
Страница 156: ... 149 HWE10060 GB X Attachments 1 R407C saturation temperature table 151 ...
Страница 157: ... 150 HWE10060 GB ...
Страница 159: ... X Attachments 152 HWE10060 GB ...