Line and Trunk Options
8380-383-115-BA
43
Issue 2, June 1999
8. 15. 121 - Inter-ring Timing
When the Dialer detects incoming ringing, the ringing is validated by measuring the inter-ring
timing. For example, if the standard of incoming ringing is two seconds on and four seconds
off, the inter-ring timing is the time in which a ring burst ends and another one begins. Once
the second ring burst begins, the timer is reset.
8. 16. 122 - Repeat Call Attempt
The number of retries for a call attempt is programmable, with 15 retries being the highest
number allowed.
8. 17. 123 - Dialer Operation on Off-hook
The Dialer can be programmed to perform a variety of operations upon off-hook. The
operations are dialling direct, dialling using hot line and dialling using Search Tables.
Note 1: If 123 = 0, the Dialer will not allow emergency numbers to be dialled, nor will the
Dialer allow
✳
initialisation or MF4 programming.
Register
Description
121 T
T = 0 for no inter-ring timing
T = 5 for 5 seconds
T = 1 for 1 second
T = 6 for 6 seconds
T = 2 for 2 seconds T = 7 for 7 seconds
T = 3 for 3 seconds T = 8 for 8 seconds
T = 4 for 4 seconds T = 9 for 9 seconds
Refer to Appendix 2 for country-specific-default data.
Register
Description
122 T
T = 0 for no retries T = 4 for 4 retries T = 8 for 8 retries
T = 1 for 1 retry
T = 5 for 5 retries T = 9 for 9 retrie
T = 2 for 2 retries T = 6 for 6 retries T =
✳
for 10 retries
T = 3 for 3 retries T = 7 for 7 retries T = # for 15 retries
Refer to Appendix 2 for country-specific-default data.
Register
Descriptio
123 T
T = 0 for immediately dial the Default Route defined
by register 124 (hot line operation)
T = 8 for using Search Tables (active Dialer)
T = 9 for dialling direct (inactive Dialer)
Refer to Appendix 2 for country-specific-default data.
Содержание SmarT-1 380-003-FBCLXX
Страница 1: ... Installation Programming Guide ...
Страница 12: ...Regulatory Information 8380 383 115 BA 11 Issue 2 June 1999 ...
Страница 16: ...SMarT 1 EuroRoute One line Dialer Installation 8380 383 115 BA 15 Issue 2 June 1999 ...
Страница 18: ...System Requirements 8380 383 115 BA 17 Issue 2 June 1999 ...
Страница 22: ...Initialisation 8380 383 115 BA 21 Issue 2 June 1999 ...
Страница 26: ...Security Access Registers 8380 383 115 BA 25 Issue 2 June 1999 ...
Страница 48: ...Line and Trunk Options 8380 383 115 BA 47 Issue 2 June 1999 ...
Страница 56: ...Access Control Sequences 8380 383 115 BA 55 Issue 2 June 1999 ...
Страница 66: ...Search Tables 8380 383 115 BA 65 Issue 2 June 1999 ...
Страница 70: ...Common Option Data 8380 383 115 BA 69 Issue 2 June 1999 ...
Страница 76: ...Call Home 8380 383 115 BA 75 Issue 2 June 1999 ...
Страница 78: ...Cost Centre Code Options 8380 383 115 BA 77 Issue 2 June 1999 ...
Страница 90: ...Appendix 2 Defaults Loaded By Using the 942 918 X Command 8380 383 115 BA 89 Issue 2 June 1999 ...
Страница 94: ...Appendix 4 Hardware Specification 8380 383 115 BA 93 Issue 2 June 1999 ...