General Notes on Programming
8380-383-115-BA
31
Issue 2, June 1999
6. 9. Load Default Data (942 918 X)
After the high-level command 942 918 X is entered while in programming mode, the entire
database, with exception of the peg counters, will be reset to the country-specific default data
values defined by the value of X.
•
X = 0 for EuroRoute
•
X = 1 for UK
•
X = 2 for Italy
•
X = 3 for Spain
•
X = 4 for France
•
X = 5 for Netherlands
•
X = 6 for Germany
•
X = 7 for Portugal.
6. 10. Load Default Data (942 903)
After the high-level command 942 903 is entered at anytime while in programming mode, the
entire database, with exception of the peg counters, will be reset to the factory default values
determined by the value of X used in the high-level command 942 918 X (refer to 6.9 for more
information the country-specific defaults).
6. 11. Clear Search Tables (942 904)
After the high-level command 942 904 is entered at anytime while in programming mode, the
entire Search Table database will be erased. This includes the following Search Table sets:
•
801 - 815
•
821 - 835
•
841 - 845.
No other registers are affected by using this command.
6. 12. Display Power-on Counter (961)
A new peg counter has been added that records the number of times the unit goes through its
power up sequence. This enables the maintainer to see how many times the Dialer has lost its
power since installation. The peg counter will read a random figure until the Dialer is first
✳
initialised. This will set the peg counter to 0000. After each successive power down/up
sequence the peg counter will be incremented by 1. The peg counter will only be reset to zero
again if the unit is
✳
initialised. The maximum peg count is 9999. Using command 961 will
display the peg counter.
6. 13. Display Route and Line Peg Counter Data (967)
The contents of the Route and Line Peg Counters can be displayed by using the 967 high-level
command while in terminal/modem programming mode. The counter does not reset when
using this command.
Содержание SmarT-1 380-003-FBCLXX
Страница 1: ... Installation Programming Guide ...
Страница 12: ...Regulatory Information 8380 383 115 BA 11 Issue 2 June 1999 ...
Страница 16: ...SMarT 1 EuroRoute One line Dialer Installation 8380 383 115 BA 15 Issue 2 June 1999 ...
Страница 18: ...System Requirements 8380 383 115 BA 17 Issue 2 June 1999 ...
Страница 22: ...Initialisation 8380 383 115 BA 21 Issue 2 June 1999 ...
Страница 26: ...Security Access Registers 8380 383 115 BA 25 Issue 2 June 1999 ...
Страница 48: ...Line and Trunk Options 8380 383 115 BA 47 Issue 2 June 1999 ...
Страница 56: ...Access Control Sequences 8380 383 115 BA 55 Issue 2 June 1999 ...
Страница 66: ...Search Tables 8380 383 115 BA 65 Issue 2 June 1999 ...
Страница 70: ...Common Option Data 8380 383 115 BA 69 Issue 2 June 1999 ...
Страница 76: ...Call Home 8380 383 115 BA 75 Issue 2 June 1999 ...
Страница 78: ...Cost Centre Code Options 8380 383 115 BA 77 Issue 2 June 1999 ...
Страница 90: ...Appendix 2 Defaults Loaded By Using the 942 918 X Command 8380 383 115 BA 89 Issue 2 June 1999 ...
Страница 94: ...Appendix 4 Hardware Specification 8380 383 115 BA 93 Issue 2 June 1999 ...