General Notes on Programming
8380-383-115-BA
27
Issue 2, June 1999
If You Hear
will be heard, if you remain inactive in the programming mode for more than sixty
seconds. After two minutes of inactivity, you will automatically exit programming mode and
any changes made will be lost.
Note: If
is heard while the FAX machine or phone is first taken off hook, a Ram
Checksum Error has occurred (Refer to page 12).
If You Hear
(long) means you have made an incorrect programming entry.
Note: In the event of an invalid entry wait for the four tones to stop and then retry the entry. No
data will be accepted by the Dialer for an incorrect programming entry.
6. 4. Programming With a Terminal
All local and remote terminal programming will be done with a V.21 300 baud modem.
Programming begins at V.21 300 baud, and if a carrier is not detected from the caller within the
time specified in the 011 Register, the Dialer will default back to MF4 mode programming.
Refer to page 80 for valid Dialer inputs.
6. 4. 1. Local Programming
The line side of the modem is connected to the telephone wall plug with a local-adaptor cable.
There must be a PABX/Centrex line port, or simulated PABX/Centrex line port present on the
line-out side of the Dialer. The user then has the modem seize the line and dial #0
✳
(Register
609 default password for all country-specific defaults), which initiates local mode
programming. If the password found in Register 609 matches the password dialed by the
modem, the Dialer enters into programming mode. If no modem carrier is detected by the
Dialer after T seconds, as specified in Register 011, the Dialer will default to MF4
programming mode. The following screen appears upon entering modem programming mode.
8380 REV 156B01 COPYRIGHT 1991-1999 MITEL INC. ALL RIGHTS RESERVED.
Serial Number BC00000000
ENTERING PROG. MODE
V>
Telephone wall plug
PABX
To AC receptacle
To
Exchange
Line
PC or Terminal
equipped with Modem
SMarT-1
Содержание SmarT-1 380-003-FBCLXX
Страница 1: ... Installation Programming Guide ...
Страница 12: ...Regulatory Information 8380 383 115 BA 11 Issue 2 June 1999 ...
Страница 16: ...SMarT 1 EuroRoute One line Dialer Installation 8380 383 115 BA 15 Issue 2 June 1999 ...
Страница 18: ...System Requirements 8380 383 115 BA 17 Issue 2 June 1999 ...
Страница 22: ...Initialisation 8380 383 115 BA 21 Issue 2 June 1999 ...
Страница 26: ...Security Access Registers 8380 383 115 BA 25 Issue 2 June 1999 ...
Страница 48: ...Line and Trunk Options 8380 383 115 BA 47 Issue 2 June 1999 ...
Страница 56: ...Access Control Sequences 8380 383 115 BA 55 Issue 2 June 1999 ...
Страница 66: ...Search Tables 8380 383 115 BA 65 Issue 2 June 1999 ...
Страница 70: ...Common Option Data 8380 383 115 BA 69 Issue 2 June 1999 ...
Страница 76: ...Call Home 8380 383 115 BA 75 Issue 2 June 1999 ...
Страница 78: ...Cost Centre Code Options 8380 383 115 BA 77 Issue 2 June 1999 ...
Страница 90: ...Appendix 2 Defaults Loaded By Using the 942 918 X Command 8380 383 115 BA 89 Issue 2 June 1999 ...
Страница 94: ...Appendix 4 Hardware Specification 8380 383 115 BA 93 Issue 2 June 1999 ...