Mirrow Moovo LN4 Series Скачать руководство пользователя страница 2

English – 

3

English

GENERAL SAFETY WARNINGS AND
PRECAUTIONS

STEP 1 

Working in safety!

4

Installation warnings

4

KNOWLEDGE OF THE PRODUCT AND PREPARATION 
FOR INSTALLATIONE

STEP 2

2.1

- Product description and intended use

5

2.2

- Components used to set up a complete system

5

STEP 3

Preliminary checks for installation

6

3.1

- Checking suitability of the environment and gate to be automated

6

3.2

- Checking product application limits

6

STEP 4

4.1

- Preliminary set-up work

7

- 4.1.

1 - Typical reference system

7

- 4.1.

2 - Establishing positions of components

7

- 4.1.

3 - Establishing the positions of the gearmotor

7

- 4.1.

4 - Establishing the device connection layout 

7

- 4.1.

5 - Checking the tools required for the work

8

- 4.1.

6 - Completing the set-up work

8

4.2

- Preparing the electrical cables 

8

INSTALLATION: COMPONENT ASSEMBLY AND
CONNECTIONS

STEP 5

Installing the automation components

9

STEP 6

System device installation and connection

11

6.1

- Selection the gearmotor position with respect to the gate, on the

control unit

12

6.2

- Installing and connecting flashing light mod. MF

12

6.3

- Installing and connecting photocells mod. MP

14

Selecting the photocell pair operating mode

15

6.4

- Installing and connecting keypad mod. MK

16

6.5

- Installing buffer battery mod. MB

17

POWER SUPPLY CONNECTION

STEP 7

18

INITIAL START-UP AND ELECTRICAL CONNECTION
CHECK

STEP 8

18

PROGRAMMING THE AUTOMATION

STEP 9

9.1

- Memorising the devices connected by means of “Bus” cable and the leaf 

“Closing” and “Opening” limit positions

19

9.2

- Memorisation of transmitter mod. MT4

20

9.3

- Programming keypad mod. MK

20

ADJUSTMENTS AND OTHER OPTIONAL FUNCTIONS

10

- Automation operation adjustment

21

11

- Memorisation of a new transmitter with control unit “in the vicinity”

21

12

- Deleting data from the control unit memory

22

13

- Automation testing and commissioning

22

14

- Installing and connecting a buffer battery

22

WHAT TO DO IF ...

(troubleshooting guide)

23

TASKS RESERVED FOR QUALIFIED TECHNICIANS

Connecting the automation to the electrical mains with a cable other than 

that supplied

24

Automation testing and commissioning

25

Product disposal

25

TECHNICAL SPECIFICATIONS OF PRODUCT
COMPONENTS

26

Enclosures: “TECHNICAL DOCUMENTATION”

I - VII

CONTENTS

Содержание Moovo LN4 Series

Страница 1: ......

Страница 2: ...unit 12 6 2 Installing and connecting flashing light mod MF 12 6 3 Installing and connecting photocells mod MP 14 Selecting the photocell pair operating mode 15 6 4 Installing and connecting keypad m...

Страница 3: ...If this is the first time you are setting up an automation for sliding gates we recommend that you read this entire manual with care This is prefer able before any work without any hurry to start prac...

Страница 4: ...trol unit can memorise up to 150 keys of MT4 transmitters up to 4 MK control keypads or alternatively up to 4 pairs of MP photocells set for the opening command only Connections of the various devices...

Страница 5: ...f accidental impact Ensure that the selected surfaces for fixing the photocells are flat and enable correct alignment between photocells 3 2 CHECKING PRODUCT APPLICATION LIMITS To ascertain suitabilit...

Страница 6: ...nals on the control unit mixed this configuration is a combination of the two configurations described above To select the most suitable connection configuration for the connection of all system devic...

Страница 7: ...edded in concrete and other preparation work for the installation can be com pleted to finalise the site ready for subsequent installation operations In particular for digging the pit for anchoring th...

Страница 8: ...fectly level use a spirit level 04 When the concrete is solid after a few days loosen and remove the upper nuts of the plate which are no longer required 05 Remove the gearmotor cover using a screwdri...

Страница 9: ...t so move the bracket to this position and if necessary use a hacksaw to cut off the excess section of the rack leaving a free section of approx 5 cm IMPORTANT the rack must not protrude from the gate...

Страница 10: ...NECTIONS OF SYSTEM DEVICES Install and connect the system devices with reference to the STEPS below and the example in fig 17 CAUTION Incorrect connections can cause faults or hazards therefore ensure...

Страница 11: ...icates execution of each manoeuvre It is also con nected to the diagnostics system of the control unit and in the event of malfunctions signals the type of problem by means of a pre set sequence of fl...

Страница 12: ...the cap of the flashing unit in its seat until the tabs click in place 21 20 22 08 Fig 23 Refit the transparent cover in its seat and turn clockwise taking care that the serrated section engages with...

Страница 13: ...p by pushing down one side as shown in the figure 02 Fig 26 Using a screwdriver open and detach the base of the photocell 03 Fig 27 a Drill a hole on the pre cut section on the base for routing the co...

Страница 14: ...oceed as follows 01 Open the cover of the photocell 02 In fig 31 locate the position in which the specific photocells are installed 03 In Table 2 select the required configuration and insert electric...

Страница 15: ...ypad cover by pushing down one side as shown in the figure 02 Fig 33 Using a screwdriver open and detach the base of the keypad 03 Fig 34 a Drill a hole on the pre cut section on the base for routing...

Страница 16: ...id the risk of leaks of harmful sub stances Battery disposal CAUTION Even if discharged the batteries can contain pollutant sub stances and therefore must NEVER be disposed of in common waste col lect...

Страница 17: ...nnections refer also to the paragraph What to do if 41 L2 green led L1 red led Key P1 STEP 7 WARNINGS The PVC power supply cable supplied serves exclusively for automation operation and programming te...

Страница 18: ...ing light 1 flash and the keypad 1 beep if fitted on the system 05 on the keypads Activate the keypads if fitted on the system by pressing any key on each one as required Successful learning is confir...

Страница 19: ...ey for example Command 2 03 Press P1 on the Control unit the same number of times as the selected command number in the example 2 i e twice and check that the green led emits the same number of quick...

Страница 20: ...press key T3 Leaf deceleration points press key T4 04 Lastly refer to Table 3 select the required value in correspondence with the selected function and on the transmitter press the key asso ciated w...

Страница 21: ...s first then the red led illuminates after 5 seconds and then both to indicate that the Control unit has entered memory deletion mode Then release the key 02 With reference to Table 4 select the data...

Страница 22: ...version of movement The automation does not respond to commands After a series of manoeuvres sent consecutively the automation is blocked The automation does not respond to commands The automation doe...

Страница 23: ...rictly observed In the case of this product the cable supplied may need to be replaced with a protected electric line suited to the installation In this case use a power cable with the dimensions 3 x...

Страница 24: ...ll devices used and the declaration of conformity compiled by the installer see section TECHNICAL DOCUMENTATION 2 Affix a dataplate on the door specifying at least the following data type of automatio...

Страница 25: ......

Страница 26: ...ered and sends the output signals Absorbed power 120mW in funzionamento 45mW in stand by Ambient operating temperature 20 50 C Use in acid saline or potentially No explosive atmospheres Assembly Verti...

Страница 27: ......

Отзывы: