Mirrow Moovo LN4 Series Скачать руководство пользователя страница 18

English – 

19

English

WARNINGS for programming:

• Always 

read

the procedure 

first

and 

then perform

the operations in the

correct sequence.

• In this manual the transmitter keys are identified by means of numbers.
To check the correspondence of 

numbers

and the transmitter 

keys

see

fig. 42

.

STEP 9

9.1

– MEMORISING THE DEVICES CONNECTED BY

MEANS OF “BUS” CABLE AND THE LEAF “CLOSING”
AND “OPENING” LIMIT POSITIONS

After ensuring correct operation of the control unit, it must be pro-
grammed as described in the sequence below:

Note

 – During this procedure, the user can exit the process at any time

(without saving the operations performed) by pressing “

P1

” once on the

control unit (

fig. 41

). In particular, from point 07 onwards, the user can

also exit the procedure by activation of a safety device (photocell or oth-
er...).

01.

(on the gate)

Release the gearmotor by means of the special release key (see
chapter “

Manually releasing or locking the gearmotor

” in the sec-

tion TECHNICAL DOCUMENTATION) and manually move the gate
leaf to mid-travel. Then lock the gearmotor again.

02.

(on the control unit)

Press and hold the key “

P1

” for at least 

5 seconds

; the green and red

Leds illuminate. Then release the key when the green led turns off (the
red led remains lit through to the end of the procedure) and proceed
as follows:

03.

(on safety Photocells)

Note

– The time available for this check is unlimited.

Check correct operation of these types of photocells, ensuring that
the relative Led flashes slowly. Otherwise if it is lit or off, correct align-
ment between the photocells attempting to obtain a flashing frequen-
cy that is slow as possible 

(the slower the flashing speed, the better

the photocell alignment)

.

• slow flashing light

= correct photocell alignment;

• light permanently lit

= incorrect alignment (revise photocell align-

ment);

• light off

= photocells installed incorrectly (check “Bus” connection of

photocells).

04.

(on control Photocells)

Activate this type of photocell (if fitted on the system), interrupting the
beam once only. Successful learning is confirmed by the flashing light

(1 flash)

and the keypad 

(1 beep)

, if fitted on the system.

05.

(on the keypads)

Activate the keypads (if fitted on the system) by pressing any key on
each one as required.

Successful learning is confirmed by 2 

beeps

at short intervals, emitted

by the keypad and 1 flash of the flashing light, if fitted on the system.

06.

(on the control unit)

Press and hold the key “

P1

” for at least 5 seconds; the green led illu-

minates and release the key when the green Led turns off.

07.

(on the gate)

At this point the ate leaf moves independently to reach the Opening
limit position.

Note

– If fine adjustments to the travel limit position are required, use

the adjustment screw inside the gearmotor as follows (

fig. 43

):

Locate the screw with the arrow corresponding to the direction in
which the leaf is moved, and adjust until the leaf reaches the required
limit position.

08.

(on the control unit)

Press and hold the key “

P1

” for at least 5 seconds; the green led illu-

minates and release the key when the green Led turns off.

09.

(on the gate)

At this point the gate leaf moves independently to reach the 

Closing

limit position.

Note

– If fine adjustments to the travel limit position are required, use

the adjustment screw inside the gearmotor as follows (

fig. 44

):

Locate the screw with the arrow corresponding to the direction in
which the leaf is moved, and adjust until the leaf reaches the
requiredlimit position.

10.

(on the control unit)

Press and hold the key “

P1

” for at least 

5 seconds

; the green led illu-

minates and release the key when the green Led turns off.

At this point the control unit independently starts 2 manoeuvres also
indicated by the flashing light:

1

Leaf opening.

2

Leaf closure.

At the end of the last manoeuvre, the red led turns off (= procedure
completed)

and then resumes flashing at regular intervals.

If the results of these checks do not conform with specifications, stop
the procedure immediately by pressing 

P1

on the control unit once.

Then repeat the entire procedure 9.1 and check correct operation of
the photocells, or modify settings of the “

Leaf sensitivity to obsta-

cles

” as described in Chapter 

10 

“Automation operation adjustment”

and if necessary check electrical connections.

PROGRAMMING THE AUTOMATION

42

T1

T3

T2

T4

43

44

Содержание Moovo LN4 Series

Страница 1: ......

Страница 2: ...unit 12 6 2 Installing and connecting flashing light mod MF 12 6 3 Installing and connecting photocells mod MP 14 Selecting the photocell pair operating mode 15 6 4 Installing and connecting keypad m...

Страница 3: ...If this is the first time you are setting up an automation for sliding gates we recommend that you read this entire manual with care This is prefer able before any work without any hurry to start prac...

Страница 4: ...trol unit can memorise up to 150 keys of MT4 transmitters up to 4 MK control keypads or alternatively up to 4 pairs of MP photocells set for the opening command only Connections of the various devices...

Страница 5: ...f accidental impact Ensure that the selected surfaces for fixing the photocells are flat and enable correct alignment between photocells 3 2 CHECKING PRODUCT APPLICATION LIMITS To ascertain suitabilit...

Страница 6: ...nals on the control unit mixed this configuration is a combination of the two configurations described above To select the most suitable connection configuration for the connection of all system devic...

Страница 7: ...edded in concrete and other preparation work for the installation can be com pleted to finalise the site ready for subsequent installation operations In particular for digging the pit for anchoring th...

Страница 8: ...fectly level use a spirit level 04 When the concrete is solid after a few days loosen and remove the upper nuts of the plate which are no longer required 05 Remove the gearmotor cover using a screwdri...

Страница 9: ...t so move the bracket to this position and if necessary use a hacksaw to cut off the excess section of the rack leaving a free section of approx 5 cm IMPORTANT the rack must not protrude from the gate...

Страница 10: ...NECTIONS OF SYSTEM DEVICES Install and connect the system devices with reference to the STEPS below and the example in fig 17 CAUTION Incorrect connections can cause faults or hazards therefore ensure...

Страница 11: ...icates execution of each manoeuvre It is also con nected to the diagnostics system of the control unit and in the event of malfunctions signals the type of problem by means of a pre set sequence of fl...

Страница 12: ...the cap of the flashing unit in its seat until the tabs click in place 21 20 22 08 Fig 23 Refit the transparent cover in its seat and turn clockwise taking care that the serrated section engages with...

Страница 13: ...p by pushing down one side as shown in the figure 02 Fig 26 Using a screwdriver open and detach the base of the photocell 03 Fig 27 a Drill a hole on the pre cut section on the base for routing the co...

Страница 14: ...oceed as follows 01 Open the cover of the photocell 02 In fig 31 locate the position in which the specific photocells are installed 03 In Table 2 select the required configuration and insert electric...

Страница 15: ...ypad cover by pushing down one side as shown in the figure 02 Fig 33 Using a screwdriver open and detach the base of the keypad 03 Fig 34 a Drill a hole on the pre cut section on the base for routing...

Страница 16: ...id the risk of leaks of harmful sub stances Battery disposal CAUTION Even if discharged the batteries can contain pollutant sub stances and therefore must NEVER be disposed of in common waste col lect...

Страница 17: ...nnections refer also to the paragraph What to do if 41 L2 green led L1 red led Key P1 STEP 7 WARNINGS The PVC power supply cable supplied serves exclusively for automation operation and programming te...

Страница 18: ...ing light 1 flash and the keypad 1 beep if fitted on the system 05 on the keypads Activate the keypads if fitted on the system by pressing any key on each one as required Successful learning is confir...

Страница 19: ...ey for example Command 2 03 Press P1 on the Control unit the same number of times as the selected command number in the example 2 i e twice and check that the green led emits the same number of quick...

Страница 20: ...press key T3 Leaf deceleration points press key T4 04 Lastly refer to Table 3 select the required value in correspondence with the selected function and on the transmitter press the key asso ciated w...

Страница 21: ...s first then the red led illuminates after 5 seconds and then both to indicate that the Control unit has entered memory deletion mode Then release the key 02 With reference to Table 4 select the data...

Страница 22: ...version of movement The automation does not respond to commands After a series of manoeuvres sent consecutively the automation is blocked The automation does not respond to commands The automation doe...

Страница 23: ...rictly observed In the case of this product the cable supplied may need to be replaced with a protected electric line suited to the installation In this case use a power cable with the dimensions 3 x...

Страница 24: ...ll devices used and the declaration of conformity compiled by the installer see section TECHNICAL DOCUMENTATION 2 Affix a dataplate on the door specifying at least the following data type of automatio...

Страница 25: ......

Страница 26: ...ered and sends the output signals Absorbed power 120mW in funzionamento 45mW in stand by Ambient operating temperature 20 50 C Use in acid saline or potentially No explosive atmospheres Assembly Verti...

Страница 27: ......

Отзывы: