GUIDE TO INSTALLATION AND OPERATION
4
| RCP-200
Connections are as follows:
USB:
two connectors on the rear panel, and two on the front panel.
GPIO:
RJ-45 connector – future use
RS-422:
RJ-45 connector – future use
ETH 10/100:
10-base-T or 100-Base-T ethernet for network connection, on an RJ-45 connector
Power Supply:
Two independent external DC power supplies can be connected to the RCP-200. The unit will detect a
supply failure and switch over to the redundant supply. The external supplies should provide 5A at 12V, positive center.
2.4 Updating the RCP-200
Your RCP-200 may need to be updated from time to time, to accommodate upgrades to system elements, for example.
You will be advised of the location of the updater file, which may be downloaded from the Miranda website.
You may wish to check the system status before updating, to be sure that the update is applicable, and after updating,
to ensure that the update was correctly installed.
Checking the system status
Push the CONFIG button located between the
two screens, to show the configuration controls
on the right-hand screen (button becomes
bright).
Touch SYSTEM – DIAG at the top of the right-
hand screen. The various elements of the
system configuration will be displayed in the
control area, as follows:
Firmware versions
Compact Flash
iControl RCP-200
Version
Boot loader
Build number
Micro code
Build date
FPGA
Hardware Info
Serial Number
CPU board
User board
iControl RCP-200
Version
Build number
Build data
Push the CONFIG button to return to device control mode (button becomes dim)